The AirTAC GAC F.R.L. Unit GAC300N08ASNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC GAC300N08ASNWT F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported unit operates within a 0.15-0.9 MPa (20-130 psi) standard pressure range and utilizes a 5 um element to trap fine particles for sensitive downstream valves. Because the air passes through the filter first, then the regulator, and finally the lubricator, the oil mist is added downstream so it never fouls the regulator seat.
This specific configuration features a nylon bowl and an automatic drain that clears condensate without an operator, which is decisive for unattended or wet lines. No gauge is supplied, but the body features a 1/8in gauge connection if you need to add one later to read the set pressure. The 60 cc condensate bowl and 98 cc oil bowl dictate the service interval, and the separate GAF300-08, GAR300-08 and GAL300-08 components can be ordered individually if only the element or bowl needs replacement. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N08ASNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered 5 um air to sensitive pneumatic tool changing mechanisms on machining centers, ensuring reliable gripping force.
Conditions air for high-speed packaging lines where the automatic drain handles condensate buildup during continuous daily operation.
Feeds clean, lubricated air to precision linear actuators used in sample handling, protecting delicate sliding surfaces from wear.
Choose this 1300 g GAC300 unit for mid-size duties where a 1/4in port is required, stepping up from the 750 g GAC200 which offers a smaller 25 cc drain bowl. The 5 um W element provides finer filtration than the standard 40 um grade, trading element service frequency for better protection of precision instruments. The automatic A drain empties condensate without manual intervention, while the nylon N bowl offers a different build material than the standard PC or metal options. Since the N after the port means no gauge is included, you must add one to the 1/8in connection to verify settings. Remember that oil mist is added downstream, so choose a filter-regulator instead if the line must stay oil-free. Stepping up to the GAC400 roughly doubles the flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet. Since the max supply is 1.0 MPa and the Standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you really need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 1/4in port, a 5 um element, a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The N in the ordering code after the port indicates no gauge is supplied. The unit has a 1/8in gauge connection, allowing you to install a separate gauge reading in MPa/psi for the default NPT thread to verify your downstream pressure settings.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.