The AirTAC GAC F.R.L. Unit GAC300N08ASNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC300N08ASNWTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported unit operates within a 0.15-0.9 MPa (20-130 psi) standard pressure range, utilizing a 5 um element to capture fine particulates before they reach sensitive valves. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the pressure-control mechanism.
Built with a nylon bowl, the assembly features an automatic drain that expels condensate without operator intervention, which is decisive for unattended machinery. No pressure gauge is supplied, but the body retains a 1/8in gauge connection for adding instrumentation later. This 1300 g unit also includes a reverse-flow (reflux) valve, which the catalogue depicts as a separate pneumatic symbol with details on its own page. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N08ASNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, lubricated air at a stable pressure to pneumatic tool changers and high-speed spindles requiring 5 um particulate control.
Conditions air for continuous-duty packaging cylinders where the automatic drain prevents moisture accumulation during multi-shift operations.
Prepares supply air for sensitive analytical actuators, with the nylon bowl offering a non-metallic option for specific chemical environments.
When sizing this assembly, note that the GAC300 flow envelope is plotted to 3000 L/min at 0.7 MPa inlet, exactly double the 1750 L/min envelope of the smaller GAC200 body. The 5 um element provides finer protection for instrument air than the standard 40 um grade, though it requires more frequent element service. If the downstream line must remain completely oil-free, this lubricator must be omitted and a separate filter-regulator chosen instead. For maintenance, the individual components are separately orderable as GAF300-08, GAR300-08 and GAL300-08, all sharing the exact same body and port suffix. The 60 cc condensate bowl holds exactly 2.4x the capacity of the 25 cc bowl found on the GAC200, meaning fewer interventions for operators.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi), with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 60 cc and the oil bowl holds 98 cc, with a total weight of 1300 g. The recommended lubricant is ISO VG 32.
No, the N in the option code means no gauge is supplied. To read the outlet pressure, you must add a circular gauge to the 1/8in connection port on the body. The default NPT thread dictates a gauge scale reading in MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.