The AirTAC GAC F.R.L. Unit GAC300N08LWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC F.R.L. combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported GAC300 body weighs 1300 g and uses a 5 um element to trap fine particles before they reach precision valves. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanism.
This specific configuration uses a nylon bowl and operates on the lower pressure range of 0.15-0.4 MPa (20-58 psi). A circular gauge reading MPa/psi is fitted for the default NPT thread, and the unit includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. Condensate is managed by a semi-auto and manual drain pair, emptying into a 60 cc bowl, while the oil reservoir holds 98 cc of ISO VG 32 lubricant. Order code GAC300N08LWTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N08LWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure solenoid valve banks on a 1/4in line where the 5 um element prevents sticking in tight-tolerance spools.
Conditions supply air for sensitive lab actuators operating under 0.4 MPa, using the nylon bowl for visual fluid checks.
Regulates gentle gripping force on delicate packaging cartons while the lubricator maintains steady cylinder speed.
Choose this 1300 g assembly when a 1/4in line requires highly filtered air at low pressure, stepping up from the GAC200's 1750 L/min plotted envelope to the GAC300's 3000 L/min at 0.7 MPa inlet for broader machine coverage. The 5 um element provides tighter filtration than the standard 40 um grade, requiring more frequent element service to protect sensitive instruments. If the downstream line must remain completely oil-free, omit the lubricator and choose a dedicated filter-regulator instead. Should a component fail, order the GAF300-08 filter, GAR300-08 regulator and GAL300-08 lubricator individually rather than replacing the whole bracket. Note that the 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum, so verify your actuators never require higher operating pressures.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) and has a max pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, features a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The K indicates a reverse-flow (reflux) valve is fitted. The catalogue displays this as a distinct pneumatic symbol, and its functional details are located on a separate page of the manual.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.