The AirTAC GAC F.R.L. Unit GAC300N08STK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported body operates at 0.15-0.9 MPa (20-130 psi) and utilizes a 40 um element. Because the units arrive pre-plumbed with quick mounting clamps, there is no inter-unit tubing to leak, drastically reducing commissioning time.
The nylon bowl equips this mid-size unit, which carries a 60 cc condensate bowl and a 98 cc oil reservoir. A circular gauge reading MPa/psi is fitted for the default NPT thread, allowing operators to monitor the set pressure directly. This specific configuration includes a reverse-flow (reflux) valve, which the catalogue illustrates as a separate pneumatic symbol with details on its own page. Order code GAC300N08STK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N08STK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable pressure to tool changer cylinders and pneumatic clamps on mid-sized CNC machining centers.
Conditions air for the 1/4in actuated valves and gripping jaws that pull and seal packaging film, ensuring consistent motion.
Supplies the necessary oil mist and regulated pressure to pneumatic pop-up diverters and sorting arms on package conveyor lines.
Choose this GAC300 body for duties requiring a plotted flow envelope reaching 3000 L/min at 0.7 MPa inlet, which is double the capacity of the smaller GAC200 (1750 L/min). The semi-auto and manual drain pair is fitted, requiring an operator to manually dump condensate or relying on the automatic pressure-drop release. If your downstream line must remain strictly oil-free, you must omit the lubricator and choose a filter-regulator instead, as this unit actively adds an oil mist downstream of the regulator seat.
Replacement spares follow the same 300-08 body-port suffix, meaning you can order GAF300-08, GAR300-08 and GAL300-08 individually rather than replacing the whole assembly. The 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, but this is strictly a safety rating and never permission to run above the 1.0 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, weighs 1300 g, holds 60 cc of condensate and 98 cc of oil, and requires ISO VG 32 or equivalent lubricant.
The K signifies that a reverse-flow (reflux) valve is attached to this F.R.L. combination. The catalogue shows this component as a distinct pneumatic symbol, and you should consult that specific page for its operational characteristics.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.