The AirTAC Airtac GAC F.R.L. Unit GAC400N15L is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/2in port, a 40 um element and a lower pressure range of 0.15-0.4 MPa (20-58 psi). The internal flow path sequences water separation first, pressure setting second and oil mist last, ensuring the regulator seat stays clean.
This model carries a nylon bowl and a fitted circular gauge reading MPa/psi for the default PT thread. Weighing 2390 g, the assembly includes a 100 cc condensate bowl and a 185 cc oil reservoir. The semi-auto and manual drain pair is fitted, dumping condensate on pressure drops or on demand.
| Model | Airtac GAC F.R.L. Unit GAC400N15L |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to looms and spinning frames where delicate yarn handling requires stable, regulated pressure up to 0.4 MPa.
Conditions air for pneumatic folding arms and suction cups on packaging lines, utilizing the 185 cc oil bowl for prolonged actuator life.
Supplies precisely regulated, lubricated air to sensitive test fixtures and small cylinders operating well below standard industrial pressures.
Choose this GAC400 body for medium-scale duties requiring a 1/2in port, noting its catalogue flow curve is plotted to 6000 L/min at 0.7 MPa inlet. The nylon bowl offers an alternative to the standard PC or metal options, sharing the exact same 1.0 MPa max pressure and -5 to 70 C thermal limits. Because this is an L type, the outlet pressure tops out at 0.4 MPa; if the machine might ever need more, the S type is the correct choice. Remember that oil mist is added downstream, so select a separate filter-regulator if the line must remain oil-free. Should the element clog, order the GAF400-15, GAR400-15 and GAL400-15 spares. The 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, uses ISO VG 32 lubricant, and features a 100 cc drain bowl with a 185 cc oil bowl.
The L type restricts the regulating range to 0.15-0.4 MPa (20-58 psi), making it unsuitable for systems requiring higher actuator force. The nylon bowl provides a different material build compared to the standard PC or metal bowls, while retaining the same 1.0 MPa maximum pressure rating.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.