verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC400 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC400N15LN

The AirTAC Airtac GAC F.R.L. Unit GAC400N15LN is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight2390 g
$123.40 $135.41Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC400N15LN

Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 40 um element, while the lower-pressure type restricts the operating band to 0.15-0.4 MPa (20-58 psi). Because the lubricator sits downstream of the regulator, oil mist never fouls the pressure-control seat.

The nylon bowl equips this unit for environments where condensate visibility is less critical than structural resilience, and no pressure gauge is supplied from the factory. A 1/4in gauge connection remains available if operators later need to read the set pressure. Condensate is managed by a paired semi-auto and manual drain, dumping liquid on pressure drops or on demand.

Airtac GAC F.R.L. Unit GAC400N15LN Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC400N15LN
SeriesGAC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight2390 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC400N15LN

GAC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC400 · 1/2" · curve to 6000 L/min
One size downGAC300
One size upGAC500 (curve to 7000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC400N15LN Is Used

factory

Textile Machinery

Feeds low-pressure loom cylinders where a 0.4 MPa ceiling prevents fabric damage while the 100 cc drain bowl captures lint and moisture.

packaging

Carton Folding Lines

Conditions air for folding actuators that rely on steady, low-force clamping, utilizing the 185 cc oil bowl to maintain consistent misting.

science

Lab Pneumatic Stations

Prepares supply for sensitive test fixtures requiring gentle actuation, with the nylon bowl offering resilience against accidental bench impacts.

Is the Airtac GAC F.R.L. Unit GAC400N15LN the Right Air-Prep Unit?

Choose this 2390 g assembly for mid-capacity air preparation, stepping down from the GAC500 which offers a 7000 L/min plotted flow envelope at 0.7 MPa inlet compared to the 6000 L/min curve printed for this body. If your machine demands standard pressure up to 0.9 MPa, select the S type instead of this L variant, as the 0.4 MPa ceiling will starve high-force actuators. Should the downstream line require absolutely oil-free air, omit the lubricator and choose a dedicated filter-regulator. Replacement spares share the 400-15 suffix: GAF400-15, GAR400-15 and GAL400-15. Note that the 0.4 MPa upper limit is 44% of the standard 0.9 MPa ceiling, so confirm your actuators can develop the required force before ordering.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 2390 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC400N15LN FAQ

This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It features a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g.

The N in the ordering code indicates that no circular gauge is supplied, meaning the set pressure cannot be read without adding one. The unit uses PT threads, and if a gauge is added later, it should match the 1/4in connection and read in MPa/psi to align with the default scale.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC400N15LN

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC400N15LN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.