The AirTAC Airtac GAC F.R.L. Unit GAC400N15LWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. It features a 1/2in port, a 5 um element for fine particle retention, and a nylon bowl. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi), making it suitable for sensitive actuators.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. The 2390 g assembly includes a semi-auto and manual drain pair, a fitted circular gauge reading MPa/psi, and a reverse-flow valve shown as a separate pneumatic symbol in the catalogue. If the downstream line must remain oil-free, select a filter-regulator instead and omit the lubricator.
| Model | Airtac GAC F.R.L. Unit GAC400N15LWK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument air to sensitive solenoid banks using the 5 um element, protecting tight tolerances in packaging machinery.
Supplies a stable 0.15-0.4 MPa output to delicate pneumatic grippers on an automated assembly line, preventing over-pressurization.
Conditions air for low-pressure actuator diverters on a conveyor, adding necessary oil mist to extend cylinder seal life.
This 1/2in unit sits in the GAC400 size class, offering a 100 cc condensate bowl and a 185 cc oil reservoir. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, double the 3000 L/min envelope of the GAC300, providing a clear path to size up or down. The 5 um element traps far finer particles than the standard 40 um grade, ideal for precision valves, though it requires more frequent service. The nylon bowl matches the standard 1.0 MPa max and -5 to 70 C limits, but confirm compatibility for aggressive surroundings. Spares follow the body-port suffix: GAF400-15, GAR400-15 and GAL400-15. Choosing the lower-pressure type means the 0.4 MPa ceiling is just 44% of the 0.9 MPa standard limit, so if the machine may ever need more pressure, this is the wrong part.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It features a 100 cc drain bowl, a 185 cc oil bowl, a 5 um element, and weighs 2390 g. Use ISO VG 32 or equivalent lubricant.
The K denotes that a reverse-flow (reflux) valve is fitted. The catalogue presents this as a distinct pneumatic symbol with its own dedicated page, and it is included as an ordering difference on this assembly.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.