The AirTAC Airtac GAC F.R.L. Unit GAC400N15SK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves standard 0.15-0.9 MPa (20-130 psi) duties, while the 40 um element captures particulates before they reach downstream valves. A circular gauge is fitted to read the set pressure in MPa/psi for the default PT thread.
The build routes air through the filter first, then the regulator, adding oil mist last so the internal seat never fouls. This variant uses a nylon bowl and includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. Weighing 2390 g, the assembly needs a firm panel or frame mount rather than relying on the tubing for support.
| Model | Airtac GAC F.R.L. Unit GAC400N15SK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic torque wrenches and actuators on a car plant conveyor, relying on the 1/2in port to maintain steady pressure during high-demand shift cycles.
Conditions air for the suction cups and folding cylinders in continuous packaging equipment, where the 40 um element prevents dust from clogging critical ejector nozzles.
Supplies regulated, lubricated air to instrument valves and grippers on a testing rig, allowing technicians to monitor the exact downstream pressure via the fitted circular gauge.
Choose this body for medium flow requirements, as the catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, double the GAC300's 3000 L/min envelope. The semi-auto and manual drain pair both ship fitted to the 100 cc condensate bowl, giving an operator flexibility during routine maintenance. If your application requires completely oil-free output downstream, omit the lubricator and select a dedicated filter-regulator instead. Replacement parts are available as GAF400-15, GAR400-15 and GAL400-15. The 1.5 MPa (215 psi) proof pressure against the 1.0 MPa (145 psi) maximum provides a 1.5x burst-test margin, which is not permission to run above the 1.0 MPa limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions within a -5 to 70 C temperature range, features a 100 cc drain bowl and a 185 cc oil bowl, uses ISO VG 32 lubricant, and weighs 2390 g.
The K indicates that a reverse-flow (reflux) valve is attached to the assembly. The official catalogue draws this as a separate pneumatic symbol with details on its own page, representing an ordering difference for specific line requirements.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.