The AirTAC Airtac GAC F.R.L. Unit GAC500C20ASNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for heavy pneumatic duty, this GAC500C20ASNWK combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/4in port serves as the inlet for a standard type system operating within 0.15-0.9 MPa (20-130 psi). A 5 um element captures fine particulates before the air reaches the regulator, while the automatic drain empties the 108 cc condensate bowl without operator intervention.
Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling. Weighing 2460 g, this assembly requires a rigid frame or panel mount rather than tubing support. The metal bowl equips this unit for demanding industrial settings, and no gauge is supplied, though a 1/4in connection is provided if you need to add instrumentation later.
| Model | Airtac GAC F.R.L. Unit GAC500C20ASNWK |
|---|---|
| Series | GAC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2460 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC500 is 1/4" if you add one.
| GAC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF500-20 filter, GAR500-20 regulator, GAL500-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAC400 |
| One size up | GAC600 (curve to 12000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a multi-station manufacturing cell where the 3/4in port and 5 um filtration protect sensitive robotic actuators from fine particulates.
Conditions air for heavy-duty bagging and palletizing machinery, with the automatic drain handling high condensate loads during continuous shifts.
Supplies lubricated air to large pneumatic clamps and tool changers, utilizing the 108 cc drain bowl to capture moisture in high-volume environments.
This assembly is built for substantial air flows, with the catalogue flow curve plotted to 7000 L/min at 0.7 MPa inlet, making it a strong candidate for multi-station machine headers. Stepping down to a GAC400 drops that plotted envelope to 6000 L/min, whereas moving up to a GAC600 extends it to 12000 L/min. The 5 um element offers superior protection for precision valves compared to the standard 40 um grade, though it will require more frequent replacement. The automatic drain clears condensate autonomously, a critical feature for unattended or wet lines. If your downstream process requires strictly oil-free air, you must omit the lubricator and choose a filter-regulator instead. The reverse-flow (reflux) valve is fitted on this model, shown as a separate pneumatic symbol in the catalogue. For maintenance, order GAF500-20, GAR500-20 and GAL500-20 spares. The 1.5 MPa proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, but this is not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates air from 0.15-0.9 MPa (20-130 psi), with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, weighs 2460 g, and features a 108 cc condensate bowl alongside a 225 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the product code indicates no gauge is supplied, but the body features a 1/4in gauge connection so you can install one to monitor your 0.15-0.9 MPa operating range. The K code means a reverse-flow (reflux) valve is fitted, which the catalogue details as a separate pneumatic symbol on its own page.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.