The AirTAC Airtac GAC F.R.L. Unit GAC500C20ASW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for heavy pneumatic lines, this GAC500C20ASW combines a filter, regulator and lubricator on a single L-shape bracket. The 3/4in port serves high-demand circuits, while the 5 um element captures fine particulates before they reach precision valves. A metal bowl houses the 108 cc condensate sump and 225 cc oil reservoir.
Air routes through the filter first, then the regulator, ensuring oil mist is added downstream so the regulating seat never fouls. The automatic drain empties condensate without an operator, and the fitted circular gauge reads MPa/psi for the default PT thread. Max pressure is 1.0 MPa (145 psi) over a -5 to 70 C range, using ISO VG 32 oil.
| Model | Airtac GAC F.R.L. Unit GAC500C20ASW |
|---|---|
| Series | GAC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2460 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF500-20 filter, GAR500-20 regulator, GAL500-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAC400 |
| One size up | GAC600 (curve to 12000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds large robotic welding arms and body panel stamping presses that consume high air volumes through 3/4in headers.
Supplies stable pressure and fine 5 um filtration to heavy-duty pneumatic grippers and lift cylinders on automated palletizers.
Protects precision air bearings and tool changers by removing fine particulates while adding necessary oil mist downstream.
Choose this 2460 g assembly for substantial air flows where panel or frame mounting is required rather than tubing support. The 5 um element provides finer protection than the 40 um standard, demanding more frequent element changes to protect downstream instruments. The metal bowl suits harsher industrial settings compared to PC or nylon alternatives. If the application requires completely dry air without oil mist, omit the lubricator and select a standalone filter-regulator. Replacement spares are GAF500-20, GAR500-20 and GAL500-20. The catalogue flow curve for the GAC500 is plotted to 7000 L/min at 0.7 MPa inlet, which is roughly 1.17x the 6000 L/min envelope of the GAC400.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 3/4in port, a 5 um element, an automatic drain, a 108 cc drain bowl capacity, a 225 cc oil bowl capacity, and weighs 2460 g. The operating temperature is -5 to 70 C using ISO VG 32 lubricant.
The 5 um W element catches far finer particles than the 40 um standard, making it ideal for sensitive valves but requiring more frequent replacement. The automatic drain clears the 108 cc condensate sump without operator intervention, which is decisive for unattended or wet lines.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.