The AirTAC Airtac GAC F.R.L. Unit GAC500C20LW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated and precisely metered air, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 3/4in port serves heavy-duty circuits, while the 5 um element captures fine particulates before they reach sensitive valves. A circular gauge is fitted, reading MPa/psi for the default PT thread.
Air passes through the filter first, then the regulator, with oil mist injected last so the internal seat stays clean. The metal bowl equips this assembly for rugged industrial settings. Operating pressure spans 0.15-0.4 MPa (20-58 psi), making it ideal for low-force actuator networks.
| Model | Airtac GAC F.R.L. Unit GAC500C20LW |
|---|---|
| Series | GAC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2460 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF500-20 filter, GAR500-20 regulator, GAL500-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAC400 |
| One size up | GAC600 (curve to 12000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air looms and spinning frames where delicate yarn handling demands a stable 0.4 MPa ceiling and fine 5 um particulate control.
Supplies metered oil mist to the folding arms and vacuum grippers of high-speed packaging equipment, preventing seal dehydration during continuous shifts.
Conditions the 3/4in main air supply for pneumatic feeders on metal stamping presses, utilizing the robust metal bowl to withstand shop-floor impacts.
Choose this 2460 g assembly for substantial air flows where a metal bowl is preferred. The 5 um element provides finer filtration than the standard 40 um grade, trapping microscopic debris at the cost of more frequent element replacement. It carries a semi-auto and manual drain pair, requiring operator interaction to expel the 108 cc condensate. If the machine requires absolutely oil-free exhaust, select a filter-regulator instead, as the lubricator here intentionally introduces oil downstream. Replacement internals share the 500-20 suffix: order GAF500-20, GAR500-20 and GAL500-20.
Stepping down, the flow envelope is plotted to 7000 L/min at 0.7 MPa inlet, exactly matching the GAC400's curve, but the 225 cc oil bowl holds roughly 22% more fluid than the GAC400's 185 cc. Because the L type tops out at 0.4 MPa, it provides only 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 108 cc drain bowl, a 225 cc oil bowl, a 5 um element, and weighs 2460 g. The recommended lubricant is ISO VG 32.
The 5 um element traps far finer particles than the standard 40 um grade, suiting precision valve circuits, though it requires more frequent service. The metal bowl is selected for rugged environments where chemical exposure or physical impact might compromise standard plastic bowls.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.