The AirTAC Airtac GAC F.R.L. Unit GAC500N20ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/4in port serves the GAC500 body class, which carries a 108 cc condensate bowl and a 225 cc oil reservoir. Because the lubricator sits last in the sequence, oil mist enters the airstream downstream of the regulator seat, preventing fouling.
Configured for low-pressure duties, the unit regulates between 0.15-0.4 MPa (20-58 psi) and uses a 40 um element. The nylon bowl equips this assembly for environments where material compatibility dictates a non-metallic housing, and the automatic drain empties condensate without an operator. A reverse-flow (reflux) valve is fitted, which the catalogue depicts as a separate pneumatic symbol on its own page. No gauge is supplied, but the body features a 1/4in connection for adding one.
| Model | Airtac GAC F.R.L. Unit GAC500N20ALNK |
|---|---|
| Series | GAC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2460 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC500 is 1/4" if you add one.
| GAC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF500-20 filter, GAR500-20 regulator, GAL500-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAC400 |
| One size up | GAC600 (curve to 12000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to looms and spinning frames where delicate tensioning cylinders operate safely within the 0.15-0.4 MPa range.
Conditions air for folding and sealing actuators that require steady low pressure, preventing damage to lightweight cardboard materials.
Supplies oil-misted air to diverter gates and pushers on high-speed parcel conveyors, ensuring continuous moving-part lubrication.
Choose this 2460 g assembly for 3/4in lines requiring low-pressure control up to 0.4 MPa. If a machine ever demands higher pressure, the L type is the wrong part since it tops out at roughly 44% of the standard 0.9 MPa ceiling. The automatic drain suits unattended stations, while the 40 um element balances protection and service frequency. Because oil mist is added downstream, select a separate filter-regulator if the line must remain oil-free. Spares follow the body-port suffix exactly: GAF500-20, GAR500-20 and GAL500-20. Stepping down, the flow envelope here is plotted to 7000 L/min at 0.7 MPa inlet, matching the GAC500, whereas the GAC400 curve extends only to 6000 L/min. The 1.5 MPa proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, though it is never permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 3/4in port, a 40 um element, and a temperature range of -5 to 70 C. The drain bowl holds 108 cc and the oil bowl holds 225 cc. The unit weighs 2460 g and uses ISO VG 32 lubricant.
The N in the model code indicates no gauge is supplied. The body features a 1/4in gauge connection, allowing you to install a compatible gauge if you need to visually monitor the 0.15-0.4 MPa outlet pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.