The AirTAC Airtac GAC F.R.L. Unit GAC500N20AS is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatic lines, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/4in port pairs with a 2460 g mass, placing it firmly in a heavy-duty size class that requires a solid panel or frame mount rather than tubing support. Air passes through the 40 um element first, then the regulator, before oil mist is introduced downstream so the regulator seat never fouls.
The nylon bowl equips this unit for environments where material compatibility is prioritized, operating within the standard 0.15-0.9 MPa (20-130 psi) range. An automatic drain clears condensate from the 108 cc bowl without an operator, a decisive feature for unattended machinery. A circular gauge is fitted, reading MPa/psi for the default PT thread, allowing operators to verify the set pressure directly at the unit.
| Model | Airtac GAC F.R.L. Unit GAC500N20AS |
|---|---|
| Series | GAC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2460 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF500-20 filter, GAR500-20 regulator, GAL500-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAC400 |
| One size up | GAC600 (curve to 12000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a multi-station machine header where the 3/4in port and automatic drain sustain high air consumption without requiring manual condensate intervention during shifts.
Conditions air for heavy-duty grippers and actuators, relying on the 225 cc oil bowl to maintain a steady lubricant supply for continuous end-of-arm tooling movements.
Prepares drive air for large pneumatic clamps and tool changers, using the 40 um element to protect precision valves from particulate ingress.
Choose this 3/4in body when a machine header demands a high flow capacity, noting the catalogue flow curve for the GAC500 is plotted to 7000 L/min at 0.7 MPa inlet. Stepping down to the GAC400 drops that envelope to 6000 L/min, whereas moving up to the GAC600 extends it to 12000 L/min. The 108 cc condensate bowl and 225 cc oil bowl dictate the service frequency; this assembly is attended far less often than a smaller body. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF500-20, GAR500-20 and GAL500-20, so a damaged bowl does not require replacing the whole assembly. The 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, which is a safety rating rather than permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The standard type operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C using ISO VG 32 lubricant. The unit weighs 2460 g, features a 108 cc drain bowl and a 225 cc oil bowl, and uses a 40 um element.
The A in the ordering code specifies an automatic drain that expels condensate from the 108 cc bowl without operator intervention, making it ideal for wet lines or unattended installations. The nylon bowl material shares the exact same 1.0 MPa pressure and -5 to 70 C temperature limits as the metal and PC options, so buyers should confirm chemical compatibility for aggressive surroundings.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.