The AirTAC Airtac GAC F.R.L. Unit GAC500N20SNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatic setups, this GAC500N20SNW combines a filter, regulator and lubricator on a single L-shape bracket. The 3/4in port serves high-flow duties, while the 5 um element captures fine particulates before they reach sensitive valves. Because the lubricator sits last in the sequence, oil mist enters the downstream line without fouling the regulator seat.
Weighing 2460 g, this unit relies on a solid panel mount rather than tubing support. The nylon bowl handles standard 1.0 MPa max pressure across the -5 to 70 C range. No gauge is supplied, but a 1/4in connection allows adding one to verify the 0.15-0.9 MPa (20-130 psi) operating band.
| Model | Airtac GAC F.R.L. Unit GAC500N20SNW |
|---|---|
| Series | GAC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2460 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC500 is 1/4" if you add one.
| GAC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF500-20 filter, GAR500-20 regulator, GAL500-20 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAC400 |
| One size up | GAC600 (curve to 12000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds large robotic welding arms and body framing actuators where a 3/4in supply line maintains adequate pressure under simultaneous cylinder firing.
Conditions air for heavy-duty vacuum chuck arrays and bagging clamps, with the 5 um element protecting tight-tolerance venturi nozzles from grit.
Supplies clean, lubricated air to multi-station machining centers for tool changers and air-blast clearing, relying on the 225 cc oil bowl for extended shifts.
Choose this 3/4in body for substantial air requirements, stepping up from the GAC400 which plots to 6000 L/min at 0.7 MPa inlet versus this body's 7000 L/min envelope. The 5 um element suits instrument air or precision pneumatics, trading off a higher restriction for finer filtration than the 40 um standard. If your process requires strictly oil-free delivery, omit the lubricator and select a filter-regulator instead.
The semi-auto and manual drains pair with a 108 cc condensate sump and a 225 cc oil reservoir, dictating the maintenance rhythm. Replacement spares follow the body-port suffix exactly: GAF500-20, GAR500-20 and GAL500-20. Stepping to this size from the GAC400 yields a 1.17x increase in plotted flow envelope (6000 to 7000 L/min at 0.7 MPa inlet).
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 108 cc drain bowl, a 225 cc oil bowl, weighs 2460 g, and uses ISO VG 32 or equivalent lubricant.
The N in the ordering code indicates no gauge is supplied from the factory. The body features a 1/4in gauge connection, allowing you to install a compatible PT-thread gauge reading in MPa/psi to monitor your specific 0.15-0.9 MPa setpoint.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.