The AirTAC Airtac GAC F.R.L. Unit GAC600C25S is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air straight to a machine header, the AirTAC GAC600C25S is a full F.R.L. combination rather than a lone filter regulator. Air passes through a 40 um filter, a pressure regulator and a lubricator, all pre-plumbed on a single L-shape bracket with quick mounting clamps. This 1in port model carries a standard pressure range of 0.15-0.9 MPa (20-130 psi) and uses a metal bowl.
Weighing 4600 g, this body demands a solid frame or panel mount instead of relying on downstream tubing for support. The assembly provides a 205 cc condensate bowl alongside a 410 cc oil reservoir, extending the interval between maintenance visits. A circular gauge is fitted, reading MPa/psi for the default PT thread, so operators can verify the set pressure at a glance.
| Model | Airtac GAC F.R.L. Unit GAC600C25S |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 1" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-25 filter, GAR600-25 regulator, GAL600-25 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 1" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a primary 1in plant air header distributing regulated, lubricated air to multiple robotic welding and material handling stations.
Supplies the main pneumatic manifold for large filling cappers and case erectors where a steady 0.9 MPa supply operates dozens of cylinders.
Conditions air for heavy-duty stamping presses and large-bore actuators that require substantial flow and continuous oil mist for moving parts.
Choose this 1in port unit for high-demand pneumatic lines, keeping in mind the GAC600 body is offered solely with a metal bowl and standard pressure type. The 205 cc drain bowl uses a semi-auto and manual drain pair, where the semi-auto dumps condensate on each pressure drop and the manual acts on demand. Because oil mist is added downstream of the regulator, select a separate filter-regulator if your line must remain strictly oil-free. Should a component fail, the three units are separately orderable as GAF600-25, GAR600-25 and GAL600-25. The catalogue flow curve for the GAC600 is plotted to 12000 L/min at 0.7 MPa inlet, which is 1.7x the 7000 L/min envelope of the GAC500.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1in port, a 40 um element, a 205 cc drain bowl, a 410 cc oil bowl, and weighs 4600 g. The operating temperature is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The metal bowl is fitted with both a semi-auto and a manual drain, allowing condensate to discharge automatically on pressure drops or manually as needed. A circular gauge is included, and because the thread is PT, the scale reads in MPa/psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.