The AirTAC Airtac GAC F.R.L. Unit GAC600C25SNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for heavy-duty pneumatics, this AirTAC GAC600C25SNW F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1in port pairs with a 4600 g mass, placing it in the largest size class where rigid frame mounting is required rather than tubing support. The 5 um element captures fine particles for sensitive valve protection, while the standard pressure range operates from 0.15-0.9 MPa (20-130 psi).
Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Because the code carries an N after the port, no gauge is supplied; the 1/4in gauge connection allows operators to add instrumentation later. The 205 cc condensate bowl and 410 cc oil bowl minimize maintenance interventions, and the metal bowl suits demanding industrial environments.
| Model | Airtac GAC F.R.L. Unit GAC600C25SNW |
|---|---|
| Series | GAC600 F.R.L. combination |
| Port size | 1" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 205 cc |
| Capacity of oil bowl | 410 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 4600 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC600 is 1/4" if you add one.
| GAC600 | GA600 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: Metal (C) only. |
| 25 | Port size 1". This body offers 20 = 3/4", 25 = 1". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) only. |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF600-25 filter, GAR600-25 regulator, GAL600-25 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC600 · 1" · curve to 12000 L/min |
|---|---|
| One size down | GAC500 |
| Build order | Filter → bracket → regulator → lubricator |
Feeds a multi-station machine header requiring high flow capacity and fine 5 um filtration to protect robotic actuators.
Conditions air for large pneumatic clutches and brakes where a 4600 g assembly and 1in port handle substantial air volume.
Supplies oil-misted air to heavy-duty pneumatic grippers and cylinders, utilizing the 410 cc oil bowl for extended operation.
Choose this metal-bowl GAC600 unit for high-demand air preparation, stepping up from the GAC500 which offers a 7000 L/min plotted flow envelope at 0.7 MPa inlet. This body pushes that sizing curve to 12000 L/min. The semi-auto and manual drain pair handles condensate removal, while the 5 um element trades standard 40 um particle capture for finer protection at the cost of more frequent element service. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. Spares follow the same body-port suffix: GAF600-25, GAR600-25 and GAL600-25. Stepping from the GAC500 to this GAC600 gives roughly 1.7x the flow envelope at 0.7 MPa inlet.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, features a 205 cc drain bowl, a 410 cc oil bowl, weighs 4600 g, and uses ISO VG 32 lubricant.
The N in the option code indicates no gauge is supplied. The body has a 1/4in gauge connection, allowing you to install a PT-threaded gauge reading MPa/psi to match your operator's standard scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.