verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAF400 · Air Filter (Water & Particulate Filter)

Airtac GAF Filter GAF400N15JW

The AirTAC Airtac GAF Filter GAF400N15JW is a genuine compressed-air filter. Its diversion structure spins the air to separate liquid water and trap solid particles down to 5 µm, protecting downstream valves and tools. It has 1/2" ports and a 100 cc drain bowl. It is a filter only — it does not regulate or set pressure.

  • TypeAir filter
  • Port size1/2"
  • Filtering grade5 µm
  • Pressure range0.15 - 0.9 MPa
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Drain bowl100 cc
  • Weight640 g
$41.70 $48.20Save 13% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAF Filter GAF400N15JW

The GAF400N15JW is a filter-only unit that spins incoming air to throw liquid water and solid particles into its 100 cc nylon drain bowl, while the 5 um HDPE core traps fine grain. It cleans the air; it does not regulate pressure and carries no gauge.

This 1/2in-port model weighs 640 g, placing it in the mid-size GAF400 class where a proper panel or frame mount is needed rather than support from the tubing. Its nylon bowl is a build choice for the environment, and you should confirm compatibility for aggressive surroundings since no chemical or temperature data is printed.

Airtac GAF Filter GAF400N15JW Technical Specifications

ModelAirtac GAF Filter GAF400N15JW
SeriesGAF400 air filter
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
BracketNot included (J)
FluidAir
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
ElementHDPE filter core
Weight640 g

Specifications follow the official AirTAC GAF catalogue (pages 225-226). Air must not freeze in the unit. This is a filter only — it separates water and solid particles but does not set or hold a downstream pressure. To regulate pressure as well, use the matching GAFR400 filter-regulator.

Model Code: Airtac GAF Filter GAF400N15JW

GAF400GA400 series air filter — sets the port range, drain-bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
JNo bracket (J) — supplied without the mounting bracket.
WFiltering grade 5 µm.
(blank)PT port thread.

A GAF has no regulator and no pressure gauge — there is no type, gauge or reflux code. Need to regulate pressure too? The matching GAFR400-15 is the same filter with a built-in regulator.

Size Class & Flow Envelope

  • GAF2001/8"-1/4" · 3000 L/min
  • GAF3001/4"-1/2" · 6000 L/min
  • GAF4003/8"-1/2" · 8000 L/min
  • GAF5003/4" · 9000 L/min
  • GAF6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. A filter this size drops less pressure at flow than the same-body GAFR filter-regulator, so match it to your peak demand.

This modelGAF400 · 1/2" · curve to 8000 L/min
One size downGAF300
One size upGAF500 (curve to 9000 L/min)
Add regulationGAFR400-15 (filter + regulator)

Where the Airtac GAF Filter GAF400N15JW Is Used

precision_manufacturing

Precision Valve Protection

Feed a bank of precision pneumatic valves on a machining center with 5 um filtered air, keeping fine abrasive dust out of spool and poppet clearances.

engineering

Instrument Air Pre-Filter

Protect sensitive instrumentation or gauges downstream by removing water droplets and solid grain before the air reaches calibrated devices.

factory

Machine Tool Line

Install on a 1/2in line feeding a single machine tool with multiple actuators, where the 100 cc bowl supports a full shift before manual draining.

Is the Airtac GAF Filter GAF400N15JW the Right Filter?

Choose the GAF400 body when 1/2in ports and a 100 cc drain bowl fit your line; it sits between the GAF300 (60 cc bowl, 6000 L/min curve) and the GAF500 (108 cc bowl, 9000 L/min curve). The nylon bowl here is a material choice, while the 5 um element (W) traps finer particles than the 40 um standard at the cost of more frequent element service. This unit ships without the mounting bracket (J), so plan for a panel mount or an existing bracket, and match your fittings to the PT port thread. If you also need a set pressure, use the matching GAFR400-15 filter-regulator instead. The 100 cc drain bowl holds about 1.67x the condensate of the GAF300's 60 cc bowl, meaning fewer drain interventions at this size.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Element 40 µm (general) or 5 µm (fine)
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Bracket kept or removed (J)
  • ✓ Need pressure control too? Use GAFR400
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: IN to OUT, bowl accessible.
  • check Place the filter FIRST in the air-prep train, ahead of any regulator or lubricator.
  • check Keep pressure at or below the 1.5 MPa (215 psi) proof limit.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 640 g unit on its bracket, not on the tubing.

This is a filter only — it removes water and solid particles but adds no pressure control and no lubrication. Add a GAR regulator, a GAL lubricator, or step up to the GAFR400-15 filter-regulator as your air-prep needs grow.

Airtac GAF Filter GAF400N15JW FAQ

This is a filter-only unit with a 5 um filtering grade, a working pressure range of 0.15-0.9 MPa (20-130 psi), a proof pressure of 1.5 MPa (215 psi), and a temperature range of -5 to 70 C. It has a 100 cc drain bowl, weighs 640 g, and its flow curve is plotted to 8000 L/min.

The J code means the mounting bracket is omitted, so you must use a panel mount or an existing bracket. The N code means the bowl is made of nylon, which is a build choice; the common specification is identical to PC or metal bowls, so confirm compatibility for your specific environment.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAF Filter GAF400N15JW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAF400N15JW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.