verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC20006SWK

The AirTAC Airtac GAFC Air Service Unit GAFC20006SWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight590 g
$66.73 $74.93Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC20006SWK

This GAFC20006SWK is a compact F.R.L. combination built as two pieces on one T-bracket: a filter-regulator body followed by a lubricator. With a 1/8" port and 590 g mass, it suits small jigs and single actuators where panel space is tight. The 5 um element traps fine particles, and the circular gauge reads in MPa/psi.

The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 1.0 MPa (145 psi) maximum. The 25 cc condensate bowl and 36 cc oil bowl set the service interval, and the semi-auto drain dumps on pressure drop while the manual drain works on demand. A reverse-flow valve is fitted, and the unit must not freeze in service.

Airtac GAFC Air Service Unit GAFC20006SWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC20006SWK
SeriesGAFC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC20006SWK

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR200-06 filter & regulator, GAL200-06 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/8" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC20006SWK Is Used

precision_manufacturing

Precision Jig Fixtures

Feed a small clamping jig on a CNC fixture with clean, regulated air at a set pressure, while the 5 um element protects fine pneumatic valves from particle wear.

handyman

Bench Assembly Stations

Power a single air tool or a small slide on a manual assembly bench, where the compact 590 g body mounts easily on a light frame or panel.

science

Lab Air Supply

Supply a lab test rig that needs oil-misted air for a small cylinder, with the 5 um filter keeping the line clean and the gauge showing the set pressure.

Is the Airtac GAFC Air Service Unit GAFC20006SWK the Right Air-Prep Unit?

Choose this GAFC200 when your line is 1/8" and loads are light; the GAFC300 with a 3/8" port and 3500 L/min envelope at 0.7 MPa inlet is the next step up. The PC bowl is standard, while C and N options change material only, not the 1.0 MPa rating. The semi-auto plus manual drain pair suits attended lines, and the 5 um element filters finer than the 40 um standard, though it needs more frequent service. The PT thread sets the gauge scale to MPa/psi, and the K code adds the reverse-flow valve. Spares are GAFR200-06 and GAL200-06, both orderable separately. With a 1.0 MPa max supply, there is only about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure carefully if you need the full output.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-06 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC20006SWK FAQ

The GAFC20006SWK operates from 0.15 to 0.9 MPa (20-130 psi) with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. Temperature range is -5 to 70 C. The drain bowl holds 25 cc and the oil bowl 36 cc. Recommended lubricant is ISO VG 32. The unit weighs 590 g.

The K code specifies a reverse-flow (reflux) valve fitted to the unit. It is shown as a separate pneumatic symbol in the catalogue. The spares for this model are the GAFR200-06 filter-regulator and the GAL200-06 lubricator, both orderable separately.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC20006SWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC20006SWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.