The AirTAC Airtac GAFC Air Service Unit GAFC30015S is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GAFC30015S is an F.R.L. combination that pairs a filter-regulator with a lubricator on a single T-bracket, using quick clamps for mounting. The filter and regulator share one body, so this 1/2in unit delivers all three functions in just two pieces, reducing the number of inter-unit seals compared to a three-body train. Air is cleaned and set to pressure first, then the lubricator adds a controlled oil mist downstream, so oil never travels back through the regulator seat.
This standard-pressure model operates from 0.15 to 0.9 MPa (20-130 psi) with a 40 um element. The 60 cc condensate bowl and 98 cc oil bowl give a reasonable service interval for a 1020 g unit, while the circular gauge with an MPa/psi scale shows the setpoint. The catalogue flow curve plots to 3500 L/min at 0.7 MPa inlet, which helps when sizing for a specific duty point.
| Model | Airtac GAFC Air Service Unit GAFC30015S |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in line to a lathe's tool changer, where the filter removes moisture and the regulator holds 0.5 MPa for the clamping cylinders while the lubricator oils the slide ways.
Supply a multi-station packaging conveyor where several 1/2in branches feed pusher cylinders, keeping the air clean and lubricated for consistent cycle times.
Prepare air for a bench assembly station with pneumatic screwdrivers and small presses, where the 60 cc bowl handles typical condensate between shifts.
Choose the GAFC30015S when you need a 1/2in port with the standard 0.15-0.9 MPa (20-130 psi) range and a PC bowl. The blank drain code means both a semi-auto drain, which dumps condensate when pressure drops, and a manual drain for on-demand use are fitted. The 40 um element suits general shop air, while the W option upgrades to 5 um for finer filtration. PT threads come with an MPa/psi gauge scale, and the K option adds a reverse-flow valve. The filter-regulator and lubricator are orderable separately as GAFR300-15 and GAL300-15, so a damaged bowl or clogged element does not require replacing the whole assembly. With a 1.0 MPa max supply, there is only about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan for a supply near 1.0 MPa if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
The GAFC30015S works with air, filters to 40 um, and regulates from 0.15 to 0.9 MPa (20-130 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 60 cc, the oil bowl holds 98 cc, and the unit weighs 1020 g. Use ISO VG 32 oil in the lubricator.
The GAFC30015S combines a filter and regulator in one body, then adds a lubricator on a shared bracket. This means you get filtering, pressure control, and oil mist in two units instead of three, so there is one less joint to seal. The filter-regulator is the GAFR300-15 and the lubricator is the GAL300-15, both orderable separately.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.