The AirTAC Airtac GAFC Air Service Unit GAFC300C15LW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300C15LW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 1/2in port and 1020 g mass place it in the mid-range class, suitable for feeding a single machine station or a small bank of cylinders. The metal bowl is specified by the C code, and the unit carries both a 60 cc condensate bowl and a 98 cc oil bowl.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), and the 5 um element traps finer particles than the standard 40 um grade. A circular gauge is fitted, reading in MPa and psi for the PT thread. Air is filtered and set to pressure in the first body, then the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat.
| Model | Airtac GAFC Air Service Unit GAFC300C15LW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-station clamping fixture on a CNC machine, where the 5 um element protects fine pneumatic valves and the lower pressure range suits delicate workholding.
Supply a small bank of air cylinders on a light assembly line, with the 60 cc condensate bowl handling moisture from a modest compressor run.
Power a lab-scale pneumatic actuator or test rig, where the 0.4 MPa ceiling and fine filtration keep instrument air clean and at a controlled low pressure.
Choose this GAFC300C15LW when your line needs fine 5 um filtration and a lower 0.4 MPa ceiling, and the metal bowl suits your environment. The semi-auto drain dumps condensate on each pressure drop, while the manual drain gives on-demand control. The PT thread carries a gauge scaled in MPa and psi, matching the default catalogue option. If a reverse-flow valve is required, the K option adds it, but it is not fitted here. Spare parts are the GAFR300-15 filter-regulator and the GAL300-15 lubricator, both orderable separately.
Since the lubricator is meant to carry oil, this set is not for oil-free air lines; select a plain GAFR if no oil mist is allowed. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, giving a comfortable margin for supply fluctuations while staying within the rated band.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
The GAFC300C15LW operates from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures and needs ISO VG 32 lubricant. The drain bowl holds 60 cc, the oil bowl 98 cc, and the unit weighs 1020 g with a 1/2in port.
The C code specifies a metal bowl, which is a build choice for the environment. The catalogue gives the same 1.0 MPa max and -5 to 70 C rating for all bowl materials, so confirm the metal suits your surroundings rather than assuming it is tougher. The bowl holds 60 cc of condensate.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.