The AirTAC Airtac GAFC Air Service Unit GAFC300C15LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300C15LWK is a two-piece F.R.L. combination: a filter-regulator body handles filtration and pressure setting, then a separate lubricator adds a metered oil mist downstream. The 1/2in port and 1020 g mass place it in the mid-size class, suited for feeding a single machine station or a small multi-actuator circuit.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 5 um element trapping fine particles for sensitive valves. The metal bowl and semi-auto plus manual drain handle condensate, while the circular gauge reads in MPa and psi. A reverse-flow valve is fitted, and the two units are separately orderable as GAFR300-15 and GAL300-15.
| Model | Airtac GAFC Air Service Unit GAFC300C15LWK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of precision pneumatic valves on a packaging machine that requires stable, lower-pressure actuation below 0.4 MPa, with fine 5 um filtration to protect sensitive spools.
Maintain a gentle, regulated air supply for conveyor belt tensioning rollers on an assembly line, where the lower pressure range prevents over-tensioning and the metal bowl resists shop-floor impacts.
Supply a laboratory test bench with clean, regulated air at a fixed low pressure for calibration fixtures, using the 5 um element to keep instrument orifices clear and the gauge for precise setpoint verification.
Choose this model when your circuit needs a regulated band capped at 0.4 MPa, not the standard 0.9 MPa ceiling. The 5 um element suits precision pneumatic controls, but expect more frequent element service than a 40 um unit. The metal bowl is a build choice; confirm it fits your environment since the catalogue lists no material-specific ratings. The semi-auto drain dumps condensate when pressure drops, with a manual backup for on-demand purging. The fitted gauge shows MPa and psi on a PT thread. For oil-free lines, omit the lubricator and select a plain GAFR300-15 instead. The reverse-flow valve is included per the K code. With 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates on air from 0.15 to 0.4 MPa (20-58 psi), with a maximum supply pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and uses ISO VG 32 oil. The drain bowl holds 60 cc and the oil bowl 98 cc, with a total weight of 1020 g.
The L code sets a regulated ceiling of 0.4 MPa instead of the standard 0.9 MPa, which suits delicate actuators or processes that must never see higher pressure. With a 1.0 MPa max supply, you have 0.6 MPa of headroom above the top setting, so the regulator can maintain its setpoint without being starved. If your machine may ever need more than 0.4 MPa, this is the wrong part.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.