verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC300 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC300C15LWK

The AirTAC Airtac GAFC Air Service Unit GAFC300C15LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1020 g
$86.35 $95.87Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC300C15LWK

This GAFC300C15LWK is a two-piece F.R.L. combination: a filter-regulator body handles filtration and pressure setting, then a separate lubricator adds a metered oil mist downstream. The 1/2in port and 1020 g mass place it in the mid-size class, suited for feeding a single machine station or a small multi-actuator circuit.

The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 5 um element trapping fine particles for sensitive valves. The metal bowl and semi-auto plus manual drain handle condensate, while the circular gauge reads in MPa and psi. A reverse-flow valve is fitted, and the two units are separately orderable as GAFR300-15 and GAL300-15.

Airtac GAFC Air Service Unit GAFC300C15LWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC300C15LWK
SeriesGAFC300 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl60 cc
Capacity of oil bowl98 cc
Recommended lubricantISO VG 32 or equivalent
Weight1020 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC300C15LWK

GAFC300GA300 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC300 · 1/2" · curve to 3500 L/min
One size downGAFC200
One size upGAFC400 (curve to 6000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC300C15LWK Is Used

precision_manufacturing

Precision valve control

Feed a bank of precision pneumatic valves on a packaging machine that requires stable, lower-pressure actuation below 0.4 MPa, with fine 5 um filtration to protect sensitive spools.

conveyor_belt

Conveyor tensioning

Maintain a gentle, regulated air supply for conveyor belt tensioning rollers on an assembly line, where the lower pressure range prevents over-tensioning and the metal bowl resists shop-floor impacts.

engineering

Test bench air supply

Supply a laboratory test bench with clean, regulated air at a fixed low pressure for calibration fixtures, using the 5 um element to keep instrument orifices clear and the gauge for precise setpoint verification.

Is the Airtac GAFC Air Service Unit GAFC300C15LWK the Right Air-Prep Unit?

Choose this model when your circuit needs a regulated band capped at 0.4 MPa, not the standard 0.9 MPa ceiling. The 5 um element suits precision pneumatic controls, but expect more frequent element service than a 40 um unit. The metal bowl is a build choice; confirm it fits your environment since the catalogue lists no material-specific ratings. The semi-auto drain dumps condensate when pressure drops, with a manual backup for on-demand purging. The fitted gauge shows MPa and psi on a PT thread. For oil-free lines, omit the lubricator and select a plain GAFR300-15 instead. The reverse-flow valve is included per the K code. With 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 60 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1020 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC300C15LWK FAQ

This F.R.L. combination operates on air from 0.15 to 0.4 MPa (20-58 psi), with a maximum supply pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and uses ISO VG 32 oil. The drain bowl holds 60 cc and the oil bowl 98 cc, with a total weight of 1020 g.

The L code sets a regulated ceiling of 0.4 MPa instead of the standard 0.9 MPa, which suits delicate actuators or processes that must never see higher pressure. With a 1.0 MPa max supply, you have 0.6 MPa of headroom above the top setting, so the regulator can maintain its setpoint without being starved. If your machine may ever need more than 0.4 MPa, this is the wrong part.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC300C15LWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC300C15LWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.