The AirTAC Airtac GAFC Air Service Unit GAFC300C15SN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC300C15SN combines a filter and regulator in one body with a separate lubricator, mounted on a shared T-bracket for a compact two-piece air prep train. The 1/2in port and 1020 g mass place it in the mid-range size class, suitable for feeding a single machine station or a short distribution line. Air enters, solids and moisture are removed, pressure is set to the 0.15-0.9 MPa (20-130 psi) range, and a controlled oil mist is added last, downstream of the regulator seat.
The metal bowl (C code) is specified here, and the common specification of 1.0 MPa max pressure and -5 to 70 C operation applies unchanged; confirm the material suits your environment. The 40 um element handles standard shop air, while the 60 cc condensate bowl and 98 cc oil bowl define the service interval. No gauge is supplied with this model, so the set pressure cannot be read without adding one to the 1/8in gauge connection.
| Model | Airtac GAFC Air Service Unit GAFC300C15SN |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a clean, regulated air supply with metered oil mist to a CNC lathe's tool changer cylinder, where consistent lubrication extends seal life and reduces sticking.
Supply a 1/2in header that powers multiple pneumatic actuators on an automotive assembly station, with the 60 cc bowl handling condensate between shifts.
Protect a case packer's pneumatic valves and cylinders with filtered, regulated, lubricated air, reducing wear on high-cycle components in a dusty environment.
Choose the GAFC300 body for a balance of flow and footprint, with the 1/2in port suiting applications that need more capacity than the 1/4in GAFC200 but less than the 3/4in GAFC500. The metal bowl is a build choice, not a performance upgrade, and the standard type regulates from 0.15 to 0.9 MPa (20-130 psi) with a max supply of 1.0 MPa. The semi-auto drain dumps condensate on each pressure drop, while the manual drain gives on-demand control. A 5 um element (W code) is available for finer filtration, and the PT thread with MPa/psi gauge scale is the default. If the line must stay oil-free, choose a plain GAFR filter-regulator instead of this lubricating set. Spare parts are orderable as GAFR300-15 and GAL300-15. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
The GAFC300C15SN operates on air with a standard pressure range of 0.15-0.9 MPa (20-130 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 60 cc drain bowl and a 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant.
The C code specifies a metal bowl, which is a build choice for the unit; the shared specification of 1.0 MPa max and -5 to 70 C does not change with material. The N after the port code means no gauge is supplied, so you would need to add one to the 1/8in gauge connection to read the set pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.