The AirTAC Airtac GAFC Air Service Unit GAFC300N15ALW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC300N15ALW is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. Air is cleaned and set to pressure in the first body, then the lubricator adds a metered oil mist last, so the regulator seat never sees oil. With a 1/2in port and 1020 g mass, it suits mid-size machine circuits where a panel or frame mount is expected.
The lower-pressure L type regulates from 0.15 to 0.4 MPa (20-58 psi), and the 5 um element traps finer particles than the standard 40 um grade for sensitive valves. The nylon bowl holds 60 cc of condensate and the oil bowl 98 cc, while the automatic drain clears water without an operator. A circular gauge is fitted, reading in MPa and psi for the PT thread, and the unit is rated -5 to 70 C with ISO VG 32 oil recommended.
| Model | Airtac GAFC Air Service Unit GAFC300N15ALW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feeds a bank of 1/2in solenoid valves on a packaging machine, where the 5 um element keeps fine particles out of valve pilots and the lower pressure range prevents over-stroking small actuators.
Serves a parts-washing station with high humidity in the air supply, where the automatic drain clears water from the 60 cc bowl without an operator and the nylon bowl resists the damp environment.
Supplies a 1/2in test fixture that must stay below 0.4 MPa, using the L-type regulator to hold a stable low setpoint while the lubricator oils a reciprocating cylinder.
Choose this GAFC300N15ALW when your line needs 1/2in ports and a regulated ceiling of 0.4 MPa. The nylon bowl is a build choice, not a performance upgrade, so confirm it suits your environment; the automatic drain is the right call for unattended or wet lines. The 5 um element protects precision equipment but will need service sooner than a 40 um grade. Spares are orderable as the GAFR300-15 filter-regulator and the GAL300-15 lubricator, both matching this body and port. If the line must stay oil-free, omit the lubricator and choose a plain GAFR filter-regulator instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
The GAFC300N15ALW operates from 0.15 to 0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It is rated for -5 to 70 C, uses ISO VG 32 lubricant, has a 60 cc drain bowl and 98 cc oil bowl, and weighs 1020 g. The 5 um element and automatic drain are fitted, and the PT thread carries a circular gauge reading MPa and psi.
The L type is designed for applications that need a lower regulated pressure band, topping out at 0.4 MPa (58 psi) instead of the standard 0.9 MPa. If your machine may ever require more than 0.4 MPa at the actuator, this is the wrong part, and you should select the standard S type instead. The 1.0 MPa max supply still applies, but the regulator cannot be set above 0.4 MPa.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.