The AirTAC Airtac GAFC Air Service Unit GAFC300N15LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC300 F.R.L. combination pairs a filter-regulator with a lubricator on a single T-bracket, so the air is cleaned and set to pressure in the first body, then the lubricator adds a controlled oil mist last. With a 1/2in port and a 1020 g mass, it suits medium-duty lines where a smaller unit would struggle to feed multiple actuators.
The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), and the 5 um element traps finer particles than the standard 40 um grade. The nylon bowl holds 60 cc of condensate and the oil bowl holds 98 cc, so the service interval is set by how wet the line is. No gauge is supplied; the 1/8in gauge connection is there if you add one later.
| Model | Airtac GAFC Air Service Unit GAFC300N15LNW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of precision pneumatic valves on a packaging line where the 5 um element protects fine internal passages from particle wear.
Supply a 1/2in header that runs several conveyor belt actuators, where the 98 cc oil bowl keeps lubricant flowing between shifts.
Set up a lab test bench needing regulated air at 0.3 MPa for cylinder cycling, with the lower-pressure range giving finer adjustment at that level.
Choose the GAFC300 body for a 1/2in port with a 3500 L/min flow envelope at 0.7 MPa inlet, which is double the GAFC200's 1750 L/min curve. The nylon bowl is a build choice, but the shared specification of 1.0 MPa max and -5 to 70 C applies to all bowl materials, so confirm it suits your surroundings. The semi-auto drain dumps condensate on each pressure drop, and the manual drain is there for on-demand use; the 5 um element needs more frequent service than the 40 um standard, so weigh that against the finer filtration.
The L type tops out at 0.4 MPa, so if your machine may ever need more pressure, this is the wrong part. The PT thread comes with an MPa/psi gauge scale, but since no gauge is fitted, you would need to add one to read the set pressure. Spares are orderable as GAFR300-15 and GAL300-15. Max supply of 1.0 MPa leaves about 0.6 MPa above the 0.4 MPa top of the range, so the regulator has plenty of inlet headroom to hold its setpoint.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 60 cc, the oil bowl holds 98 cc, and the unit weighs 1020 g.
The N after the port code means no gauge is supplied. The GAFC300 body has a 1/8in gauge connection, so you can add a gauge later if you need to read the set pressure directly. The PT thread option would normally come with an MPa/psi scale gauge, but this version omits it to reduce cost.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.