The AirTAC Airtac GAFC Air Service Unit GAFC300N15LW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Air enters the GAFC300N15LW and first passes through a nylon-bowled filter that removes moisture and solid particles down to 5 um, then through the regulator, which holds the outlet at a lower-pressure band of 0.15-0.4 MPa (20-58 psi). The lubricator, mounted downstream on the same T-bracket, then adds a controlled ISO VG 32 oil mist to the air stream, so the three functions happen in the correct order without oil ever travelling back through the regulator seat.
This 1/2in-port combination weighs 1020 g and carries a 60 cc condensate bowl plus a 98 cc oil bowl, which sets the service rhythm for the unit. The circular gauge, graduated in MPa and psi, is fitted so the set pressure is visible at a glance. With a 1.0 MPa (145 psi) maximum supply, the unit leaves about 0.6 MPa of headroom above its 0.4 MPa top setting, so a supply near the maximum is needed to reach the upper end of the range.
| Model | Airtac GAFC Air Service Unit GAFC300N15LW |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 5 um-filtered, lower-pressure supply to pilot-operated valves on a packaging line, where the 0.4 MPa ceiling protects delicate actuators from over-pressurization.
Supply oil-misted air to a slideway lubrication system on a CNC lathe, where the 98 cc oil bowl supports extended runs between refills.
Condition air for pneumatic hand tools at a workbench assembly station, using the 1/2in port to feed multiple tools from one filtered and regulated source.
The GAFC300 body suits medium-duty lines where a 1/2in port and a 3500 L/min flow curve (plotted at 0.7 MPa inlet) are appropriate. The nylon bowl is the build choice here; the catalogue gives no impact or chemical data for bowl materials, so confirm it suits your environment. The semi-auto drain dumps condensate when pressure drops, while the manual drain handles it on demand. The 5 um element traps finer particles than the standard 40 um grade, which protects precision valves but requires more frequent element service. The PT thread carries a gauge scale in MPa/psi, matching the fitted circular gauge. If the line must stay oil-free, omit the lubricator and choose a plain GAFR300-15 filter-regulator instead. The two units are separately orderable as GAFR300-15 and GAL300-15. With a 1.0 MPa max supply, the regulated band tops out at 0.4 MPa, so the L type gives up about 44% of the standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C and it must not freeze. It has a 60 cc drain bowl and a 98 cc oil bowl, weighs 1020 g, and uses ISO VG 32 lubricant. The 5 um element filters the air before regulation.
The L in the code specifies the lower-pressure type, which tops out at 0.4 MPa (58 psi) instead of the standard 0.9 MPa (130 psi). The W indicates a 5 um element, which traps finer particles than the standard 40 um grade. This combination suits applications with sensitive components that need both fine filtration and a limited pressure ceiling.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.