The AirTAC Airtac GAFC Air Service Unit GAFC300N15SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC300N15SNK is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator is a separate unit joined on a T-bracket with quick clamps. Air is cleaned and set to pressure in the first body, then a metered oil mist is added downstream, so oil never crosses the regulator seat. The 1/2in port and 1020 g mass place it in the mid-size class, needing a proper panel mount rather than tubing support.
The nylon bowl holds 60 cc of condensate and the oil bowl 98 cc, which sets the service rhythm for this unit. The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 40 um element and no gauge supplied (the 1/8in gauge connection is there if one is added later). A reverse-flow valve is fitted, shown as a separate symbol in the catalogue. The semi-auto drain dumps on pressure drop, with a manual override for on-demand emptying.
| Model | Airtac GAFC Air Service Unit GAFC300N15SNK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-station clamping fixture on a CNC mill where the 1/2in port delivers enough air for a pair of cylinders, and the 40 um element protects the valve spools from fine shop dust.
Run the stop-gate cylinders on a light assembly conveyor with this unit, using the semi-auto drain to clear condensate on each line shutdown and the manual drain for scheduled maintenance.
Supply a carton-erecting machine's folding and sealing actuators, where the 98 cc oil bowl keeps the mist topped up through a full shift and the nylon bowl suits a dry, indoor environment.
Choose this GAFC300N15SNK when a 1/2in port suits your line and you want the nylon bowl option, which is a build choice - the 1.0 MPa max and -5 to 70 C rating are identical across PC, metal and nylon, so confirm the material fits your surroundings. The semi-auto plus manual drain pair works for attended stations; step to the A code for automatic draining. The 40 um element is the standard grade, and the PT thread carries a MPa/psi gauge scale if you add a gauge later. The reverse-flow valve is fitted per the K code, and the two units are separately orderable as GAFR300-15 and GAL300-15. If your line must stay oil-free, omit the lubricator and choose a plain GAFR instead. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan the supply near 1.0 MPa if you need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C and must not freeze. The drain bowl holds 60 cc and the oil bowl 98 cc, with a total weight of 1020 g. Recommended lubricant is ISO VG 32 or equivalent. The 40 um element filters the air, and the unit has a 1/2in port.
The N after the port code means no gauge is supplied with this unit. The gauge connection on the GAFC300 body is 1/8in, so you can add a circular gauge later if you need to read the set pressure. Without one, the regulated output cannot be verified visually, so plan for a gauge if your process requires a confirmed setting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.