The AirTAC Airtac GAFC Air Service Unit GAFC300N15SNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC300 F.R.L. combination cleans the air with a 5 um element, sets pressure to 0.15-0.9 MPa (20-130 psi), then adds a metered oil mist from the lubricator. The filter and regulator share one body, so the whole set is two pieces on a T-bracket with quick clamps, not three separate units.
The 1/2in port and 1020 g mass put it in the mid-size class for shop air. Its 60 cc condensate bowl and 98 cc oil bowl set the service rhythm. A nylon bowl is fitted, and the gauge connection is 1/8in since no gauge ships with this model.
| Model | Airtac GAFC Air Service Unit GAFC300N15SNWK |
|---|---|
| Series | GAFC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1020 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC300 is 1/8" if you add one.
| GAFC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR300-15 filter & regulator, GAL300-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC300 · 1/2" · curve to 3500 L/min |
|---|---|
| One size down | GAFC200 |
| One size up | GAFC400 (curve to 6000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
The 5 um element filters fine particles that could clog small pilot valves on a CNC machine's tool changer, while the regulator holds a stable setpoint for consistent actuation.
Feed a multi-station assembly fixture with cleaned, regulated air and a controlled oil mist to keep pneumatic slides and grippers moving smoothly on a 1/2in branch line.
Provide a clean, pressure-stable air source for a lab test bench where a 5 um filter protects sensitive flow meters and the lubricator maintains cylinder performance.
The GAFC300 body with a 1/2in port suits branch lines feeding several actuators. The nylon bowl is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C applies, so confirm the material fits your environment. The 5 um element traps finer particles than the standard 40 um, useful for precision valves, but expect more frequent element service. Both semi-auto and manual drains are fitted, so condensate dumps on pressure drop or on demand. The reverse-flow (reflux) valve is included, and the catalogue shows it as a separate pneumatic symbol. For spares, order GAFR300-15 and GAL300-15 separately. With a 1.0 MPa max supply, you have about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan supply pressure carefully if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR300-15 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It is rated for -5 to 70 C and uses ISO VG 32 oil. The drain bowl holds 60 cc and the oil bowl 98 cc, with a total weight of 1020 g.
The N in the code after the port means no gauge is supplied. If you need to read the set pressure, you can add one to the 1/8in gauge connection on the GAFC300 body. The 5 um element and nylon bowl are the other key options on this build.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.