The AirTAC Airtac GAFC Air Service Unit GAFC40015ALNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC40015ALNK is an F.R.L. combination where the filter and regulator share one body, paired with a lubricator on a T-bracket. With a 1/2in port and 1810 g mass, it suits mid-size machine headers where a 3/8in GAFC300 would be undersized. The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), and the 40 um element handles standard shop air.
The automatic drain clears the 100 cc condensate bowl without operator attention, while the 185 cc oil bowl feeds the lubricator. No gauge is fitted, so the 1/4in gauge connection is the point to add one if the set pressure needs to be read. The reverse-flow valve is fitted per the K code, and the catalogue shows it as a separate pneumatic symbol.
| Model | Airtac GAFC Air Service Unit GAFC40015ALNK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in header on a CNC lathe where the lower-pressure range suits pilot valves and coolant actuators that never need more than 0.4 MPa.
Supply a multi-fixture workbench with regulated air at 0.3 MPa for pneumatic clamps, keeping the pressure low enough to protect delicate part-holding fixtures.
Use the 0.15-0.4 MPa band on a leak-test fixture where precise low-pressure regulation is required and the automatic drain keeps the bowl clear during long test cycles.
The GAFC400 body with a 1/2in port handles flows the catalogue plots to 6000 L/min at 0.7 MPa inlet, about 70% more than the GAFC300's 3500 L/min envelope. The PC bowl is the standard build, and the automatic drain suits unattended operation. The lower-pressure L type tops out at 0.4 MPa, so if the machine may ever need more, choose the S type instead. The 40 um element is the default; the W option gives 5 um for finer filtration. PT thread with the gauge scale in MPa/psi applies here, though no gauge is supplied. The reverse-flow valve is fitted, and the two units are orderable separately as GAFR400-15 and GAL400-15. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g.
The N in the code after the port means no gauge is supplied. The gauge connection on the GAFC400 body is 1/4in, so a gauge can be added at that port if the set pressure needs to be monitored. The thread is PT with the scale in MPa/psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.