The AirTAC Airtac GAFC Air Service Unit GAFC40015ASNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC40015ASNK is an F.R.L. combination built from two units on a T-shape bracket: a GAFR filter-regulator (filter and regulator share one body) plus a GAL lubricator. Air is filtered and pressure-set in the first body, then the lubricator adds a controlled oil mist last, downstream of the regulator. With a 1/2in port and 1810 g mass, this size class suits mid-size machine headers or multi-actuator stations, and needs a proper panel or frame mount rather than tubing support.
The working range is 0.15-0.9 MPa (20-130 psi), with a 40 um element and an automatic drain that clears condensate without an operator. The 100 cc condensate bowl and 185 cc oil bowl define the service interval: the larger capacity means fewer interventions compared to a GAFC200's 25 cc drain bowl. A reverse-flow (reflux) valve is fitted, and no gauge is supplied, so the gauge connection is 1/4in if one is added later.
| Model | Airtac GAFC Air Service Unit GAFC40015ASNK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in header supplying solenoid valves on a CNC lathe's coolant system, where the automatic drain keeps condensate out of the valve bank during long unmanned shifts.
Power a multi-station pick-and-place unit on an assembly line, with the 185 cc oil bowl keeping gripper cylinders lubricated across a full shift without frequent topping up.
Condition air for a carton erector's pneumatic cylinders and sensors, where the 100 cc drain bowl and automatic drain reduce maintenance stops in a dusty packaging hall.
Choose the GAFC400 for a 1/2in port with a flow envelope plotted to 6000 L/min at 0.7 MPa inlet, stepping up from the GAFC300's 3500 L/min curve. The bowl is PC (blank code), which shares the same 1.0 MPa max and -5 to 70 C rating as metal or nylon options; confirm the material suits your surroundings. The automatic drain (A) is ideal for unattended lines, while the standard type (S) regulates 0.15-0.9 MPa (20-130 psi). No gauge is fitted (N), so plan to add one at the 1/4in connection if operators need to read set pressure. The PT thread carries an MPa/psi scale, and the 40 um element handles general shop air. The reverse-flow (reflux) valve is fitted per the K code. Spares are orderable as GAFR400-15 and GAL400-15. Max supply 1.0 MPa leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan inlet pressure near 1.0 MPa if you need the full regulated output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The GAFC40015ASNK operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 100 cc drain bowl and 185 cc oil bowl, weighs 1810 g, and uses a 40 um element. The port is 1/2in with PT thread, and the automatic drain clears condensate without operator intervention.
The N in the code after the port means no gauge is supplied with the GAFC40015ASNK. The gauge connection is 1/4in, so you can add a circular gauge later if operators need to read the set pressure. The PT thread determines the gauge scale, which would be MPa/psi if a gauge is fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.