The AirTAC Airtac GAFC Air Service Unit GAFC40015ASNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC40015ASNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a T-bracket with quick clamps. Air enters the 1/2in port, gets filtered to 5 um and regulated to 0.15-0.9 MPa (20-130 psi), then the lubricator adds a metered oil mist downstream. The 1810 g unit needs a proper panel or frame mount, not support from the tubing.
The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm, and the automatic drain clears water without an operator. No gauge is supplied, so the 1/4in gauge connection is where one would be added. The reverse-flow (reflux) valve is fitted, and the PT thread carries a MPa/psi scale if a gauge is installed later. The 5 um element traps finer particles than the standard 40 um, which suits precision valves but requires more frequent element service.
| Model | Airtac GAFC Air Service Unit GAFC40015ASNWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
The 5 um element protects sensitive pneumatic valves on a CNC machine tool from fine particles that would otherwise cause sticking or premature wear.
A 1/2in port and 1810 g build suit a multi-station assembly line where each station needs filtered, regulated, lubricated air for actuators and grippers.
The automatic drain keeps condensate out of a paint spray booth's air supply, while the 5 um element removes particles that could mar a finish.
Choose this GAFC400 if your line needs 1/2in ports and the 1810 g mass tells you it is a mid-size unit. The PC bowl is the default build, and the automatic drain makes it suited for unattended operation. The 5 um element is the finer filtration option, while the standard 40 um is the default. The L type (0.15-0.4 MPa) is available on this body if you need a lower regulated band. The no-gauge code means the 1/4in connection is ready for a field-installed gauge, and the PT thread uses a MPa/psi scale. The reverse-flow valve is fitted per the K code. Spare parts are orderable as GAFR400-15 and GAL400-15. If the line must stay oil-free, choose a plain GAFR filter-regulator instead. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan a supply near 1.0 MPa if you need the full regulated output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g. The 5 um element filters the air, and the automatic drain clears condensate without an operator.
The N after the port code means no gauge is supplied with this unit. The gauge connection on the GAFC400 body is 1/4in, so you can add a field-installed gauge there if you need to read the set pressure. The PT thread uses a MPa/psi scale on any compatible gauge.