The AirTAC Airtac GAFC Air Service Unit GAFC40015LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC40015LK is an F.R.L. combination built as two units on a T-bracket: a filter-regulator body handling filtration and pressure control, then a lubricator adding oil mist downstream. The 1/2in port and 1810 g mass place it in the mid-size class, suited for machine headers feeding several actuators. It operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi), with a 40 um element and a circular gauge reading MPa/psi.
The filter and regulator share one body, so the assembly has one less inter-unit joint than a three-piece train. The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm: the oil reservoir needs attention roughly twice as often as the water trap. A reverse-flow (reflux) valve is fitted, and the semi-auto drain dumps condensate each time pressure drops, with a manual override for on-demand emptying.
| Model | Airtac GAFC Air Service Unit GAFC40015LK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a multi-point clamping fixture on a CNC machine where consistent 0.3 MPa clamping force holds thin-walled parts without distortion.
Supply a pick-and-place arm on an electronics assembly line, where the lower pressure range prevents damage to delicate components during placement.
Run a heat-sealing press on a packaging line, using the regulated 0.35 MPa output to control sealing pressure on variable product heights.
Choose the GAFC40015LK when your circuit runs below 0.4 MPa and you need a 1/2in port. The L type caps at 0.4 MPa, so if the machine may ever require more pressure, step to the standard S type instead. The PC bowl is the default build; confirm it suits your environment, as the catalogue gives no material-specific chemical or impact data. The semi-auto drain suits attended lines where operators can check the bowl, while the fitted gauge shows the setpoint on an MPa/psi scale for the PT thread. The 5 um element option (W) would trap finer particles but needs more frequent service. Spares are orderable as GAFR400-15 and GAL400-15. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure with that margin in mind.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
This F.R.L. combination works with air, filtering to 40 um and regulating from 0.15-0.4 MPa (20-58 psi). Maximum supply pressure is 1.0 MPa (145 psi), with a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 100 cc and the oil bowl 185 cc. Recommended lubricant is ISO VG 32. The complete unit weighs 1810 g.
The L code specifies a lower-pressure regulator, topping out at 0.4 MPa instead of 0.9 MPa. This suits applications needing gentle, precise pressure control, such as delicate clamping or soft-touch assembly. The trade-off is that it cannot supply higher pressures if your process changes, so verify your maximum requirement before selecting this variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.