AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC40015LNW

The AirTAC Airtac GAFC Air Service Unit GAFC40015LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$89.64 $99.38Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC40015LNW

This lower-pressure F.R.L. combination pairs a filter-regulator with a lubricator on one T-shape bracket, so the air is cleaned, set to 0.15-0.4 MPa (20-58 psi), then given a metered oil mist as the last step. The GAFC400 body takes a 1/2in port and carries a 5 um element that traps fine particles for sensitive equipment.

The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm, and the 1810 g mass shows this is a panel-mounted unit, not something supported by the tubing. No gauge is supplied, so the 1/4in gauge connection is where an operator would add one to read the set pressure.

Airtac GAFC Air Service Unit GAFC40015LNW Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC40015LNW
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC40015LNW

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC40015LNW Is Used

precision_manufacturing

Precision Fixture Clamping

Feed a 1/2in line to a pneumatic fixture that clamps delicate parts during CNC machining. The 5 um element keeps fine swarf out of the workholding valves, and the lower pressure range prevents over-clamping thin-walled components.

science

Laboratory Air Supply

Supply a lab bench with clean, oil-misted air for a small diaphragm pump or an air bearing. The 0.15-0.4 MPa band gives fine control for sensitive experiments, and the 185 cc oil bowl keeps the lubricator running between checks.

packaging

Low-Force Packaging Gripper

Run a packaging gripper that handles soft goods or filled pouches without crushing them. The lower pressure range protects the product, while the 100 cc condensate bowl handles moisture from a busy line with fewer drain checks.

Is the Airtac GAFC Air Service Unit GAFC40015LNW the Right Air-Prep Unit?

Choose the GAFC40015LNW when your line needs a 1/2in port and a regulated ceiling of 0.4 MPa (20-58 psi) - the lower-pressure type suits gentle actuators or precision blow-off work. The PC bowl is the standard build, and the 5 um element filters finer than the 40 um default, though it will need more frequent service. The semi-auto drain dumps condensate when pressure drops, with a manual override for on-demand use.

The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan the inlet pressure carefully to stay within the regulated band. Spares are the GAFR400-15 filter-regulator and GAL400-15 lubricator, both orderable separately.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC40015LNW FAQ

The GAFC40015LNW operates from 0.15 to 0.4 MPa (20-58 psi) with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. It works in -5 to 70 C temperatures and needs ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g.

The N in the code means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a circular gauge there to read the set pressure. Without one, you cannot verify the outlet pressure visually, so plan to fit a gauge if operators need to check the setting.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC40015LNW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC40015LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.