The AirTAC Airtac GAFC Air Service Unit GAFC40015LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This F.R.L. combination pairs a filter-regulator body with a lubricator on a shared T-bracket, so the air is cleaned, set to pressure, then given a metered oil mist in the final stage. The 1/2in port and 1810 g mass place it in the mid-size GAFC400 class, suited to a machine header feeding several actuators.
The lower-pressure regulator tops out at 0.4 MPa (20-58 psi), which suits delicate circuits but not plant lines that may need more. A 5 um element traps fine particles for sensitive valves, and the 100 cc condensate bowl plus 185 cc oil bowl set the service rhythm. No gauge is supplied, so the 1/4in gauge connection is left for the installer to fit.
| Model | Airtac GAFC Air Service Unit GAFC40015LNWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in line to a pneumatic press or assembly jig where the lower 0.4 MPa range protects delicate clamping forces and the 5 um element keeps fine particles off precision valve seats.
Supply a small machining center's way-lubrication system with filtered, regulated air and a controlled oil mist, using the 185 cc oil bowl to maintain consistent lubrication over a shift.
Run a laboratory test bench or calibration rig at pressures below 0.4 MPa, where the fine 5 um filtration protects sensitive instrumentation and the semi-auto drain keeps the condensate bowl clear.
Choose the GAFC40015LNWK when the line stays below 0.4 MPa and a fine 5 um element is preferred for precision equipment. The PC bowl is the standard build, and the semi-auto drain dumps condensate on pressure drops while the manual drain gives on-demand control. The reverse-flow valve is fitted, and the PT thread carries a gauge scale in MPa/psi if a gauge is added later. Spares are the GAFR400-15 filter-regulator and GAL400-15 lubricator, both orderable separately. Since the lubricator adds oil mist, select a plain GAFR filter-regulator instead if the downstream air must stay oil-free. With a 1.0 MPa max supply, the unit has about 0.6 MPa of headroom above its 0.4 MPa regulated ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates from 0.15 to 0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 100 cc condensate bowl and a 185 cc oil bowl, weighs 1810 g, and uses a 5 um filter element.
The N in the code means no gauge is supplied with this unit. The GAFC400 body has a 1/4in gauge connection, so a standard 1/4in pressure gauge can be added later if the operator needs to read the set pressure directly. The PT thread option means any gauge fitted should have an MPa/psi scale.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.