verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC40015SNK

The AirTAC Airtac GAFC Air Service Unit GAFC40015SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$100.54 $111.01Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC40015SNK

This GAFC40015SNK is a two-piece F.R.L. combination: the filter and pressure regulator share one body, and the lubricator is mounted beside it on a T-bracket. Air enters the 1/2in port, gets cleaned by the 40 um element, and is regulated to a set pressure between 0.15-0.9 MPa (20-130 psi) before oil mist is added downstream.

The 100 cc condensate bowl and 185 cc oil bowl mean fewer service stops on a medium-size line. At 1810 g, this unit needs a proper panel or frame mount rather than tubing support. The reverse-flow (reflux) valve is fitted, and no gauge is supplied - the 1/4in gauge connection is there if you add one later.

Airtac GAFC Air Service Unit GAFC40015SNK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC40015SNK
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialPC
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC40015SNK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC40015SNK Is Used

precision_manufacturing

CNC coolant lines

Feed a 1/2in line supplying coolant valves on a CNC lathe, where regulated pressure keeps flow consistent and the 100 cc bowl handles condensate between shifts.

factory

Assembly station headers

Mount on a panel feeding a multi-operator assembly station, using the 185 cc oil bowl to lubricate several pneumatic screwdrivers from one point.

engineering

Packaging machine air prep

Prepare air for a case packer's cylinder bank, where the 6000 L/min envelope at 0.7 MPa inlet covers peak demand and the semi-auto drain suits attended operation.

Is the Airtac GAFC Air Service Unit GAFC40015SNK the Right Air-Prep Unit?

Choose the GAFC400 body for 3/8in to 1/2in lines where the GAFC300's 3500 L/min envelope at 0.7 MPa inlet feels tight. The PC bowl is the standard build; the semi-auto drain dumps condensate on pressure drops, with a manual override for on-demand draining. The 40 um element suits general shop air, while the 5 um option (W code) traps finer particles for sensitive valves. This model has no gauge, so plan to read pressure with a separate gauge on the 1/4in connection. The PT thread carries an MPa/psi scale if you fit one. The reflux valve is part of this build per the K code. Spares are the GAFR400-15 filter-regulator and GAL400-15 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range, so set your supply near maximum if you need the full band.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC40015SNK FAQ

This F.R.L. combination works with air only, filtering to 40 um and regulating from 0.15-0.9 MPa (20-130 psi). Maximum supply pressure is 1.0 MPa (145 psi), with a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 100 cc and the oil bowl 185 cc. Use ISO VG 32 lubricant. The complete unit weighs 1810 g.

The N after the port code means no gauge is supplied, so you cannot read the set pressure directly on the unit - the 1/4in gauge connection is there if you add one. The K code indicates the reverse-flow (reflux) valve is fitted. This valve is shown as a separate symbol in the catalogue, and its detailed function is covered on a dedicated page.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC40015SNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC40015SNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.