verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C15ASK

The AirTAC Airtac GAFC Air Service Unit GAFC400C15ASK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$127.75 $140.07Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C15ASK

This GAFC400C15ASK is a two-piece F.R.L. combination from AirTAC: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/2in port and 1810 g mass place it in the mid-size class, a step up from the GAFC300's 1020 g for lines that need more condensate and oil capacity.

The metal bowl holds 100 cc of condensate and the oil bowl 185 cc, so the service interval is generous for a machine header. It regulates from 0.15 to 0.9 MPa (20-130 psi) with a 40 um element, and the circular gauge reads in MPa/psi. The automatic drain clears water without an operator, and the reverse-flow valve is fitted as an ordering option.

Airtac GAFC Air Service Unit GAFC400C15ASK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C15ASK
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC400C15ASK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C15ASK Is Used

precision_manufacturing

CNC coolant lines

Regulates air for a CNC machine's coolant system, where the 40 um element and automatic drain keep the line clear of moisture and the 1/2in port matches the header.

factory

Assembly station headers

Feeds a multi-station assembly line with filtered, regulated air and oil mist for pneumatic tools, with the 185 cc oil bowl reducing refill frequency.

engineering

Packaging equipment

Supplies a packaging machine's actuators and valves, where the 100 cc condensate bowl and automatic drain support continuous shifts without manual attention.

Is the Airtac GAFC Air Service Unit GAFC400C15ASK the Right Air-Prep Unit?

Choose this GAFC400C15ASK when a 1/2in port feeds a multi-station machine header. The metal bowl is specified by the C code, with the same 1.0 MPa (145 psi) max and -5 to 70 C range as PC or nylon versions, so confirm it suits your environment. The automatic drain (A) handles wet lines unattended, while the standard type (S) covers 0.15-0.9 MPa (20-130 psi) with a 40 um element and a fitted MPa/psi gauge on PT threads. The K suffix adds the reverse-flow valve, which the catalogue draws as a separate symbol. Spare parts are the GAFR400-15 filter-regulator and GAL400-15 lubricator, both orderable separately. With a 1.0 MPa max supply, you have only about 0.1 MPa above the 0.9 MPa regulated top, so plan the inlet pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C15ASK FAQ

This F.R.L. combination operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works from -5 to 70 C, uses ISO VG 32 oil, has a 100 cc drain bowl and 185 cc oil bowl, and weighs 1810 g.

The K suffix indicates a reverse-flow (reflux) valve is fitted. The catalogue shows it as a separate pneumatic symbol on its own page, and it is an ordering difference from the standard GAFC400. The unit still functions as a filter-regulator plus lubricator with the same port and pressure range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C15ASK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C15ASK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.