verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C15L

The AirTAC Airtac GAFC Air Service Unit GAFC400C15L is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$108.14 $119.13Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C15L

This AirTAC GAFC400C15L is a two-piece F.R.L. combination built around a 1/2in port body. The filter and regulator share one housing, so the set delivers filtered, pressure-controlled air before the lubricator adds a metered oil mist downstream. It weighs 1810 g and carries a 100 cc condensate bowl plus a 185 cc oil bowl.

The lower-pressure L type regulates from 0.15 to 0.4 MPa (20-58 psi), which suits machines that never need more than 58 psi. A circular gauge is fitted and reads in MPa and psi. The 40 um element handles standard shop air, while the metal bowls are a build choice for the buyer to confirm against their environment.

Airtac GAFC Air Service Unit GAFC400C15L Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C15L
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC400C15L

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C15L Is Used

precision_manufacturing

Precision pressure control

Set a precise 0.3 MPa (43 psi) for a delicate clamping fixture on a CNC machine, where the lower range gives finer adjustment than a standard regulator.

factory

Paint spray equipment

Feed a spray gun at a consistent 0.35 MPa (51 psi) for even coating, with the lubricator adding a fine oil mist to the air tool.

build

Assembly line tooling

Power a pneumatic screwdriver on an assembly bench, where the 1/2in port supports the tool's air demand and the 185 cc oil bowl keeps it lubricated.

Is the Airtac GAFC Air Service Unit GAFC400C15L the Right Air-Prep Unit?

Choose the GAFC400C15L when a 1/2in port and a lower pressure ceiling are the right fit. The metal bowl (C) is specified here, and the semi-auto drain dumps condensate on each pressure drop while the manual drain gives on-demand control. The 40 um element is the standard grade; the W option upgrades to 5 um for finer filtration. PT threads come with an MPa/psi gauge scale, and the K option adds a reverse-flow valve if needed. If the line must stay oil-free, omit the lubricator and select a plain GAFR filter-regulator instead. Spare parts are orderable as GAFR400-15 and GAL400-15.

With a 1.0 MPa max supply, this unit leaves about 0.6 MPa above the 0.4 MPa top of its regulated range, so plan the inlet pressure well above the setpoint you need.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C15L FAQ

The GAFC400C15L operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles air from -5 to 70 C and needs ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g.

The L type is designed for applications that only need up to 0.4 MPa (58 psi), offering finer adjustment in that band. If your machine might ever require more pressure, the standard type (S) with a 0.9 MPa ceiling would be the safer choice.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C15L

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C15L and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.