verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C15LK

The AirTAC Airtac GAFC Air Service Unit GAFC400C15LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$119.04 $130.76Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C15LK

This AirTAC GAFC400C15LK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 1/2in port and 1810 g mass place it in the mid-size class, suited to feeding a multi-axis machine or a small production line. It carries a 40 um element and a circular gauge reading MPa/psi.

The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum supply. Its 100 cc condensate bowl and 185 cc oil bowl define the service rhythm; the metal bowl is specified by the C code, and the reverse-flow (reflux) valve is fitted as an ordering option. The semi-auto drain dumps on pressure drop, while the manual drain works on demand.

Airtac GAFC Air Service Unit GAFC400C15LK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C15LK
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC400C15LK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C15LK Is Used

precision_manufacturing

Precision Drilling Jig

Feed a multi-spindle drilling jig with regulated air at 0.3 MPa, where the lower-pressure range prevents over-force on small workpieces.

factory

Assembly Line Pallet Stop

Power pallet stops on a conveyor assembly line, using the semi-auto drain to clear condensate during frequent pressure drops.

engineering

Test Bench Air Supply

Supply a test bench with clean, lubricated air at a set 0.35 MPa for checking pneumatic components without exceeding their rated pressure.

Is the Airtac GAFC Air Service Unit GAFC400C15LK the Right Air-Prep Unit?

Choose this GAFC400C15LK when your circuit needs a regulated 0.15-0.4 MPa band and a 1/2in port. The metal bowl is a build choice; confirm it suits your environment, as the catalogue gives no material-specific ratings. The semi-auto plus manual drain pair suits attended stations, and the fitted gauge shows MPa/psi. The reverse-flow (reflux) valve is included per the K code. If the line must stay oil-free, omit the lubricator and select a plain GAFR400-15 filter-regulator instead; the GAL400-15 lubricator is separately orderable. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C15LK FAQ

It operates on air, with a lower-pressure range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -5 to 70 C. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g. Use ISO VG 32 lubricant.

The K code specifies that a reverse-flow (reflux) valve is fitted. It appears as a separate pneumatic symbol in the catalogue. The unit also has a metal bowl (C) and a lower-pressure regulator (L), with a 1/2in port.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C15LK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C15LK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.