The AirTAC Airtac GAFC Air Service Unit GAFC400C15LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400C15LK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 1/2in port and 1810 g mass place it in the mid-size class, suited to feeding a multi-axis machine or a small production line. It carries a 40 um element and a circular gauge reading MPa/psi.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 1.0 MPa (145 psi) maximum supply. Its 100 cc condensate bowl and 185 cc oil bowl define the service rhythm; the metal bowl is specified by the C code, and the reverse-flow (reflux) valve is fitted as an ordering option. The semi-auto drain dumps on pressure drop, while the manual drain works on demand.
| Model | Airtac GAFC Air Service Unit GAFC400C15LK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a multi-spindle drilling jig with regulated air at 0.3 MPa, where the lower-pressure range prevents over-force on small workpieces.
Power pallet stops on a conveyor assembly line, using the semi-auto drain to clear condensate during frequent pressure drops.
Supply a test bench with clean, lubricated air at a set 0.35 MPa for checking pneumatic components without exceeding their rated pressure.
Choose this GAFC400C15LK when your circuit needs a regulated 0.15-0.4 MPa band and a 1/2in port. The metal bowl is a build choice; confirm it suits your environment, as the catalogue gives no material-specific ratings. The semi-auto plus manual drain pair suits attended stations, and the fitted gauge shows MPa/psi. The reverse-flow (reflux) valve is included per the K code. If the line must stay oil-free, omit the lubricator and select a plain GAFR400-15 filter-regulator instead; the GAL400-15 lubricator is separately orderable. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
It operates on air, with a lower-pressure range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -5 to 70 C. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g. Use ISO VG 32 lubricant.
The K code specifies that a reverse-flow (reflux) valve is fitted. It appears as a separate pneumatic symbol in the catalogue. The unit also has a metal bowl (C) and a lower-pressure regulator (L), with a 1/2in port.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.