verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C15LN

The AirTAC Airtac GAFC Air Service Unit GAFC400C15LN is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$102.72 $113.34Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C15LN

This AirTAC GAFC400C15LN is a two-piece F.R.L. combination: a filter and regulator share one body, and a lubricator is mounted beside it on a T-bracket with quick clamps. It handles a 1/2in port and weighs 1810 g, so it suits a machine header or a small multi-station line rather than a single actuator.

The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element and a metal bowl. The 100 cc condensate bowl and 185 cc oil bowl set the service rhythm, and the gauge connection is 1/4in if you add one later. The catalogue flow curve is plotted to 6000 L/min at 0.7 MPa inlet, which helps when sizing against a neighbouring body.

Airtac GAFC Air Service Unit GAFC400C15LN Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C15LN
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC400C15LN

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C15LN Is Used

precision_manufacturing

Precision pressure set

Set a lathe's air chuck to a stable 0.3 MPa with the lower-pressure regulator, while the lubricator meters oil to the chuck cylinder seals.

conveyor_belt

Packaging line feed

Feed a carton erector's pneumatic sensors and small cylinders on a 1/2in header, with the 100 cc bowl catching water from a humid plant air supply.

factory

Multi-station assembly

Supply a four-station assembly bench where each station has its own valve manifold, relying on the 185 cc oil bowl to keep cycle times consistent between top-ups.

Is the Airtac GAFC Air Service Unit GAFC400C15LN the Right Air-Prep Unit?

Choose the GAFC400C15LN when your line needs 1/2in ports and a regulated band that tops out at 0.4 MPa. The metal bowl is specified by the C code, and the shared specification (1.0 MPa max, -5 to 70 C) does not change with bowl material, so confirm the metal suits your surroundings. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand use, and the 40 um element is the standard grade. No gauge is supplied, so the set pressure cannot be read without adding one on the 1/4in connection; the PT thread carries an MPa/psi scale if you fit the circular gauge. The two units are orderable separately as the GAFR400-15 filter & regulator and the GAL400-15 lubricator. Because the lubricator adds oil mist last, choose a plain GAFR if the line must stay oil-free. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C15LN FAQ

This lower-pressure F.R.L. combination operates from 0.15 to 0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, holds a 100 cc condensate bowl and a 185 cc oil bowl, and weighs 1810 g. Use ISO VG 32 oil in the lubricator.

The C code specifies a metal bowl as a build choice; the catalogue gives no impact or chemical data, so confirm it suits your environment. The N after the port means no gauge is supplied, so you cannot read the set pressure without adding one on the 1/4in gauge connection.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C15LN

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C15LN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.