The AirTAC Airtac GAFC Air Service Unit GAFC400C15LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400C15LNW is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator is mounted beside them on a T-bracket. The 1/2in port and 1810 g mass place it in the mid-size class, suited to a machine header feeding several actuators. It regulates to a lower pressure band of 0.15-0.4 MPa (20-58 psi), with a 5 um element for finer filtration.
The metal bowl holds 100 cc of condensate and the oil bowl 185 cc, so service intervals are generous for a unit this size. With no gauge fitted, the 1/4in gauge connection is available if an operator needs to read the set pressure. The semi-auto drain dumps condensate on each pressure drop, while the manual drain gives on-demand control.
| Model | Airtac GAFC Air Service Unit GAFC400C15LNW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in line to a CNC spindle air curtain or tool changer with a regulated 0.4 MPa supply, keeping the pressure low and stable for sensitive components.
Supply a multi-station assembly bench where multiple pneumatic screwdrivers or pick-and-place units need a consistent, lower-pressure air source without frequent adjustment.
Use it on a laboratory test jig that requires a clean, regulated air supply at 0.4 MPa or below, with the 5 um element protecting fine orifices in measurement equipment.
Choose this GAFC400C15LNW when your line needs 1/2in ports and a regulated output capped at 0.4 MPa. The metal bowl is a build choice for the surroundings, though the shared specification of 1.0 MPa max and -5 to 70 C applies to all bowl materials, so confirm it suits your environment. The 5 um element traps finer particles than the standard 40 um, at the cost of more frequent element service. The semi-auto and manual drains are both fitted, and the PT thread carries the default MPa/psi gauge scale if you add a gauge to the 1/4in connection. If the line must stay oil-free, omit the lubricator and choose a plain GAFR400-15 filter-regulator instead; the GAL400-15 lubricator is the matching spare here. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The GAFC400C15LNW operates at 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g.
The C code specifies a metal bowl, which is a build choice; the catalogue gives no performance difference between bowl materials, so confirm it suits your environment. The N after the port means no gauge is supplied, but the 1/4in gauge connection is there if you add one later.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.