verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C15LNW

The AirTAC Airtac GAFC Air Service Unit GAFC400C15LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$102.72 $113.34Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C15LNW

This AirTAC GAFC400C15LNW is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator is mounted beside them on a T-bracket. The 1/2in port and 1810 g mass place it in the mid-size class, suited to a machine header feeding several actuators. It regulates to a lower pressure band of 0.15-0.4 MPa (20-58 psi), with a 5 um element for finer filtration.

The metal bowl holds 100 cc of condensate and the oil bowl 185 cc, so service intervals are generous for a unit this size. With no gauge fitted, the 1/4in gauge connection is available if an operator needs to read the set pressure. The semi-auto drain dumps condensate on each pressure drop, while the manual drain gives on-demand control.

Airtac GAFC Air Service Unit GAFC400C15LNW Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C15LNW
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC400C15LNW

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C15LNW Is Used

precision_manufacturing

Precision machining center

Feed a 1/2in line to a CNC spindle air curtain or tool changer with a regulated 0.4 MPa supply, keeping the pressure low and stable for sensitive components.

factory

Assembly station header

Supply a multi-station assembly bench where multiple pneumatic screwdrivers or pick-and-place units need a consistent, lower-pressure air source without frequent adjustment.

engineering

Test rig air supply

Use it on a laboratory test jig that requires a clean, regulated air supply at 0.4 MPa or below, with the 5 um element protecting fine orifices in measurement equipment.

Is the Airtac GAFC Air Service Unit GAFC400C15LNW the Right Air-Prep Unit?

Choose this GAFC400C15LNW when your line needs 1/2in ports and a regulated output capped at 0.4 MPa. The metal bowl is a build choice for the surroundings, though the shared specification of 1.0 MPa max and -5 to 70 C applies to all bowl materials, so confirm it suits your environment. The 5 um element traps finer particles than the standard 40 um, at the cost of more frequent element service. The semi-auto and manual drains are both fitted, and the PT thread carries the default MPa/psi gauge scale if you add a gauge to the 1/4in connection. If the line must stay oil-free, omit the lubricator and choose a plain GAFR400-15 filter-regulator instead; the GAL400-15 lubricator is the matching spare here. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C15LNW FAQ

The GAFC400C15LNW operates at 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 100 cc, the oil bowl 185 cc, and the unit weighs 1810 g.

The C code specifies a metal bowl, which is a build choice; the catalogue gives no performance difference between bowl materials, so confirm it suits your environment. The N after the port means no gauge is supplied, but the 1/4in gauge connection is there if you add one later.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C15LNW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C15LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.