The AirTAC Airtac GAFC Air Service Unit GAFC400C15LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400C15LNWK is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator is mounted on the same T-bracket. The 1/2in port and 1810 g mass place it in the mid-size class, suited for feeding a multi-station machine header where several actuators draw from one prepared air supply.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), and the 5 um element traps fine particles for sensitive valves. The metal bowl holds 100 cc of condensate, while the separate oil bowl holds 185 cc. No gauge is fitted, so the 1/4in gauge connection is ready for an add-on if a readout is needed later.
| Model | Airtac GAFC Air Service Unit GAFC400C15LNWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of precision pneumatic valves on a packaging line where the 5 um element protects tight clearances and the lower pressure range prevents over-energizing sensitive actuators.
Supply a 1/2in header on a multi-station assembly machine, where the 100 cc drain bowl and 185 cc oil bowl reduce how often an operator must check fluid levels across a shift.
Use on a test bench that requires a stable 0.15-0.4 MPa (20-58 psi) supply for checking cylinder seals, where the metal bowl suits a workshop environment and the gauge port allows a panel-mounted readout.
Choose the GAFC400 body for a 1/2in port with a 6000 L/min flow envelope (plotted at 0.7 MPa inlet), stepping down from the GAFC500's 7000 L/min curve when space is tighter. The metal bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The semi-auto drain dumps condensate on pressure drops, with a manual drain for on-demand use. The 5 um element filters finer than the standard 40 um, but expect more frequent element service. The L-type regulator tops out at 0.4 MPa, and the reverse-flow (reflux) valve is fitted. The gauge connection is 1/4in since no gauge ships. Spares are GAFR400-15 and GAL400-15. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g.
The C code specifies a metal bowl, which is a build choice for the unit's surroundings; the catalogue does not provide impact or chemical resistance data, so confirm it fits your environment. The N after the port means no gauge is supplied, leaving a 1/4in gauge connection for adding one later if you need to read the set pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.