The AirTAC Airtac GAFC Air Service Unit GAFC400C15SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC400 unit combines a filter-regulator and a lubricator on a single T-bracket, so the air is cleaned, set to pressure, and then given a metered oil mist in one compact assembly. The 1/2in port and 1810 g weight place it in the mid-size class, suited for feeding a multi-station machine header or a bank of actuators.
The metal bowl (C code) holds 100 cc of condensate, while the oil bowl holds 185 cc, and the 40 um element handles standard shop air. It operates from 0.15 to 0.9 MPa (20-130 psi) with a max supply of 1.0 MPa (145 psi), and the reverse-flow valve is fitted per the K code.
| Model | Airtac GAFC Air Service Unit GAFC400C15SNK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in header supplying coolant valves and cylinder actuators on a CNC lathe, where the metal bowl resists accidental knocks and the 100 cc condensate bowl handles a shift of moisture.
Power a series of pallet stops and locating pins on an automated assembly line, using the 0.15-0.9 MPa range to set precise clamping pressure and the lubricator to keep slide valves cycling.
Run a carton erector's film-seal cylinders and glue applicator valves, where the 185 cc oil bowl keeps the lubricator topped up between shifts and the semi-auto drain clears water from compressed air.
Choose this GAFC400C15SNK when you need a 1/2in port with a metal bowl and no gauge. The metal bowl is a build choice for your environment, but the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The semi-auto drain dumps condensate on each pressure drop, and the manual drain gives on-demand control. The 40 um element is the standard grade; step to the 5 um W code for finer filtration if your valves need it. The PT thread uses an MPa/psi gauge scale, but this unit ships without a gauge, so the 1/4in gauge connection is ready for one you add. The reverse-flow valve is fitted as an ordering difference. Spares are the GAFR400-15 filter-regulator and GAL400-15 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.1 MPa of headroom above the 0.9 MPa top of the regulated range, so plan your inlet pressure if you need to run near the ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and must not freeze. The drain bowl holds 100 cc and the oil bowl holds 185 cc. Use ISO VG 32 oil in the lubricator. The complete unit weighs 1810 g.
The C code specifies a metal bowl, which is a build choice for your environment, though the catalogue gives no impact or chemical data, so confirm it suits your conditions. The N after the port code means no gauge is supplied, but the 1/4in gauge connection is ready for one you add later. The reverse-flow valve is fitted per the K code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.