The AirTAC Airtac GAFC Air Service Unit GAFC400C15SNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC GAFC400C15SNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/2in port and 1810 g mass place it in the mid-size class, suited for machine headers feeding several actuators. It filters to 5 um, regulates from 0.15-0.9 MPa (20-130 psi), and the metal bowl is specified by the C code.
The filter and regulator share one housing, so the assembly has one less inter-unit joint than a three-piece filter-regulator-lubricator train. Air is cleaned and set to pressure first, then the lubricator adds a metered oil mist downstream. The 100 cc condensate bowl and 185 cc oil bowl define the service interval, and the 5 um element traps finer particles for sensitive valves, though it will need more frequent attention than a 40 um element.
| Model | Airtac GAFC Air Service Unit GAFC400C15SNWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
The 5 um element protects sensitive pneumatic valves and instrument air from fine particles, making this unit suitable for precision machining centers or assembly stations where consistent actuation matters.
With a 1/2in port and 6000 L/min flow envelope at 0.7 MPa inlet, this unit feeds a machine header serving multiple cylinders or a small production line, providing regulated and lubricated air to each branch.
The 0.15-0.9 MPa (20-130 psi) range and metal bowl suit test benches that cycle frequently, where the semi-auto drain clears condensate on each pressure drop and the 5 um element keeps test fixtures clean.
Choose this GAFC400C15SNWK when a 1/2in port and 1810 g mass fit your panel layout. The metal bowl is a build choice, not a performance upgrade - the 1.0 MPa (145 psi) maximum and -5 to 70 C range apply to all bowl materials, so confirm the metal suits your environment. The semi-auto drain dumps condensate on each pressure drop, with a manual drain for on-demand use, and the 5 um element suits precision valve circuits. No gauge is supplied, so the 1/4in gauge connection must be fitted if you need to read the set pressure. The reverse-flow (reflux) valve is fitted, and the PT thread carries a MPa/psi scale. The lubricator is meant to carry ISO VG 32 oil, so if the line must stay oil-free, choose a plain GAFR400-15 filter-regulator instead; the GAL400-15 lubricator is separately orderable. With 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated band, so plan a supply near 1.0 MPa if you need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The GAFC400C15SNWK operates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. It has a 100 cc condensate bowl and 185 cc oil bowl, weighs 1810 g, and uses ISO VG 32 lubricant. The element is 5 um and the port is 1/2in.
The N in the code after the port means no gauge is supplied with this unit. The GAFC400 body has a 1/4in gauge connection, so you can add a gauge later if you need to read the set pressure. The PT thread determines that a gauge fitted here would read in MPa and psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.