verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400C15SWK

The AirTAC Airtac GAFC Air Service Unit GAFC400C15SWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$119.04 $130.76Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400C15SWK

This GAFC400C15SWK is an F.R.L. combination where the filter and regulator share one body, and a lubricator is joined on a T bracket. With a 1/2in port and a 1810 g mass, it sits in the mid-size class, needing a proper panel or frame mount rather than support from the tubing. The 5 um element traps finer particles than the standard 40 um grade, making it a fit for circuits with precision valves or instrument air.

Air enters the first body, gets filtered and set to pressure, then the lubricator adds a controlled oil mist last. The metal bowl is specified by the C code, and the shared specification of 1.0 MPa max and -5 to 70 C applies. The circular gauge is fitted, reading in MPa and psi for the PT thread. The reverse-flow valve is also fitted, as indicated by the K code.

Airtac GAFC Air Service Unit GAFC400C15SWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400C15SWK
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC400C15SWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400C15SWK Is Used

precision_manufacturing

Precision Valve Control

Feed a bank of precision pneumatic valves on a packaging line where the 5 um element filters fine particulates that could clog small orifices.

factory

Machine Tool Lubrication

Supply a metered oil mist to a multi-spindle drilling head, where the 185 cc oil bowl supports longer runs between refills.

engineering

Test Rig Air Prep

Prepare air for a laboratory test bench with a 1/2in manifold, using the 100 cc condensate bowl to handle moisture from a wet compressor line.

Is the Airtac GAFC Air Service Unit GAFC400C15SWK the Right Air-Prep Unit?

Choose the GAFC400C15SWK when you need 1/2in ports and the 6000 L/min plotted flow envelope at 0.7 MPa inlet. The metal bowl is a build choice; confirm it suits your surroundings, as the catalogue gives no material-specific data. The drain is the semi-auto and manual pair, so condensate dumps on pressure drop or on demand. The 5 um element means more frequent service than a 40 um grade, but it protects sensitive components. The gauge reads MPa and psi, matching the PT thread. Spares are the GAFR400-15 filter-regulator and the GAL400-15 lubricator, both orderable separately. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan the supply pressure accordingly.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400C15SWK FAQ

The pressure range is 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g.

The K code indicates a reverse-flow (reflux) valve is fitted. It is shown as a separate pneumatic symbol in the catalogue. The valve is part of the assembly as ordered, and its specific function is detailed on its own catalogue page.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400C15SWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400C15SWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.