The AirTAC Airtac GAFC Air Service Unit GAFC400N15AL is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC400N15AL is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/2in port and 1810 g mass place it in the mid-size class, suited for machine headers or multi-station lines where a smaller unit would struggle.
Air enters the first body where the 40 um element removes solids and moisture, and the lower-pressure regulator sets output between 0.15-0.4 MPa (20-58 psi). The lubricator then adds a metered ISO VG 32 oil mist downstream, so oil never passes back through the regulator seat. The nylon bowl holds 100 cc of condensate, with a separate 185 cc oil bowl.
| Model | Airtac GAFC Air Service Unit GAFC400N15AL |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a multi-spindle screwdriver or press with regulated air at 0.3 MPa, where the lower-pressure range prevents over-force on delicate parts.
Supply a bank of pneumatic cylinders on a carton-erecting machine, with the automatic drain handling condensate from a humid plant line.
Operate a coolant control valve on a CNC lathe, where the 1/2in port delivers enough flow and the 0.4 MPa ceiling matches the valve's rating.
Choose this GAFC400N15AL when your circuit needs a 1/2in port and a lower regulated ceiling of 0.4 MPa (20-58 psi). The nylon bowl is a build choice; the catalogue gives no impact or chemical data, so confirm it suits your environment. The automatic drain clears condensate without operator attention, ideal for wet or unattended lines. A circular gauge is fitted, reading MPa/psi for the PT thread. Spares are orderable as GAFR400-15 and GAL400-15.
With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 100 cc and the oil bowl 185 cc. Recommended lubricant is ISO VG 32. The unit weighs 1810 g.
The L type regulates to a maximum of 0.4 MPa (20-58 psi), which suits applications needing a soft, consistent pressure without risk of over-pressurizing sensitive components. If your machine may ever require more than 0.4 MPa, the standard S type (0.15-0.9 MPa) would be the correct choice instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.