The AirTAC Airtac GAFC Air Service Unit GAFC400N15ALK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400N15ALK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. Air is filtered and set to pressure first, then the lubricator adds a metered oil mist last, so oil never travels back through the regulator seat. With a 1/2in port and a 1810 g mass, this unit suits mid-size machine headers rather than small jigs.
The nylon bowl holds 100 cc of condensate, while the oil bowl holds 185 cc, and the automatic drain clears water without an operator. The lower-pressure type regulates from 0.15 to 0.4 MPa (20-58 psi), with a 40 um element and a fitted circular gauge reading MPa/psi on the PT thread. A reverse-flow (reflux) valve is included, and the catalogue flow curve plots to 6000 L/min at 0.7 MPa inlet for sizing reference.
| Model | Airtac GAFC Air Service Unit GAFC400N15ALK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a 1/2in header on a CNC machining center where consistent lower-pressure air around 0.3 MPa (43 psi) drives workholding clamps, with the automatic drain handling condensate from the compressor.
Supply oil-misted air to a multi-station assembly line with pneumatic screwdrivers and actuators, where the 185 cc oil bowl reduces refill frequency and the 100 cc drain bowl extends maintenance intervals.
Run a packaging machine's film-sealing cylinders and grippers at a regulated 0.35 MPa (51 psi), using the 6000 L/min flow envelope at 0.7 MPa inlet to size the supply for intermittent high demand.
Choose the GAFC400N15ALK when your line needs 1/2in ports and a regulated band capped at 0.4 MPa (20-58 psi) - the L type tops out there, so if the machine may ever require more pressure, select a standard S type instead. The nylon bowl is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C does not change with material, so confirm it suits your surroundings. The automatic drain handles wet or unattended lines, and the 40 um element is the standard grade; step to a 5 um W element for finer filtration. The fitted gauge reads MPa/psi for the PT thread, and the K code adds the reverse-flow valve. Spares are orderable separately as the GAFR400-15 filter & regulator and the GAL400-15 lubricator. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range - plan the supply accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The GAFC400N15ALK operates from 0.15 to 0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It works in temperatures from -5 to 70 C and uses ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl holds 185 cc, with a total weight of 1810 g.
The L type regulates to a maximum of 0.4 MPa (58 psi), while the standard S type reaches 0.9 MPa (130 psi). This means the L type gives up about 44% of the top range, so it is only suitable for low-pressure circuits that never need more than 0.4 MPa output.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.