verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400N15ALNWK

The AirTAC Airtac GAFC Air Service Unit GAFC400N15ALNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight1810 g
$122.33 $134.27Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400N15ALNWK

This AirTAC GAFC400N15ALNWK is an F.R.L. combination that pairs a filter-regulator with a lubricator on a single T-shape bracket, reducing the piece count to two where a conventional train would need three. The 1/2in port and 1810 g mass place it in the mid-range size class, a unit that needs a proper panel or frame mount rather than support from the tubing.

The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with the 5 um element trapping fine particles for sensitive equipment. The nylon bowl holds 100 cc of condensate while the oil bowl holds 185 cc, and the automatic drain clears water without an operator. Since no gauge is fitted, the gauge connection is 1/4in if you add one later.

Airtac GAFC Air Service Unit GAFC400N15ALNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400N15ALNWK
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC400N15ALNWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400N15ALNWK Is Used

precision_manufacturing

Precision machining center

Feed a 1/2in line to a CNC machining center's tool changer, where the 5 um element protects precision valves and the lower pressure range suits sensitive actuators.

factory

Assembly station

Supply a multi-fixture assembly station with regulated air at 0.15-0.4 MPa, where the automatic drain keeps the line clear during long production runs.

engineering

Test bench

Use on a pneumatic test bench with delicate instrumentation, where the 5 um filtration and lower pressure ceiling prevent over-pressurizing components.

Is the Airtac GAFC Air Service Unit GAFC400N15ALNWK the Right Air-Prep Unit?

Choose this GAFC400N15ALNWK when your line needs 1/2in ports and a regulated output capped at 0.4 MPa (20-58 psi). The nylon bowl is a build choice, but confirm it suits your environment since the catalogue gives no material-specific ratings. The automatic drain suits unattended operation, while the 5 um element catches finer particles than the standard 40 um grade, though it will need more frequent service. The PT thread and its MPa/psi gauge scale match standard local fittings, and the reverse-flow valve is fitted as an ordering difference. Spares are orderable separately as the GAFR400-15 filter-regulator and the GAL400-15 lubricator. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the regulated range.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400N15ALNWK FAQ

This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and it uses ISO VG 32 lubricant. It has a 100 cc drain bowl and a 185 cc oil bowl, and weighs 1810 g.

The N after the port code means no gauge is supplied with this unit. The gauge connection is 1/4in if you need to add one later. The N before the port code indicates the bowl is made of nylon, which is a material choice you should confirm suits your operating environment.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400N15ALNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400N15ALNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.