The AirTAC Airtac GAFC Air Service Unit GAFC400N15ALWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400N15ALWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, joined on a T-bracket with quick clamps. The 1/2in port and 1810 g mass place it in the mid-size class, suited for machine headers or multi-station lines where a single point of air preparation is needed.
Air enters the first body where the 5 um element traps fine particles and the regulator sets pressure to 0.15-0.4 MPa (20-58 psi). The lubricator then adds a metered oil mist downstream, so oil never passes back through the regulator seat. The nylon bowl is specified by the N code, and the automatic drain clears condensate without operator attention.
| Model | Airtac GAFC Air Service Unit GAFC400N15ALWK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a CNC machining center's tool changer with regulated air at 0.15-0.4 MPa, where the 5 um element protects sensitive solenoid valves from fine abrasive dust.
Supply a multi-station assembly line's pneumatic screwdrivers with filtered, regulated air and a controlled oil mist to keep tool mechanisms running smoothly.
Power a case packer's film-sealing cylinders with a stable 0.15-0.4 MPa supply, while the automatic drain handles condensate from intermittent operation.
The GAFC400 body offers 3/8in and 1/2in ports; this 1/2in version sits above the GAFC300's 3500 L/min envelope, with the catalogue curve plotted to 6000 L/min at 0.7 MPa inlet. The L type limits regulation to 0.15-0.4 MPa (20-58 psi), so confirm your actuators never need more than that ceiling. The 5 um element traps finer particles than the standard 40 um, but will need more frequent service. The automatic drain suits wet or unattended lines, while the nylon bowl is a build choice - confirm it suits your environment. The circular gauge reads in MPa/psi, and the reverse-flow valve is fitted per the K code. Spares are orderable as GAFR400-15 and GAL400-15. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
This unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the oil bowl 185 cc. Recommended lubricant is ISO VG 32. The complete assembly weighs 1810 g.
The N before the port code specifies a nylon bowl. The catalogue gives no temperature, chemical, or impact data for bowl materials, so confirm nylon suits your environment. The L code means lower pressure regulation, and the K code indicates the reverse-flow valve is fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.