The AirTAC Airtac GAFC Air Service Unit GAFC400N15LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC400N15LK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 1/2in port and 1810 g mass place it in the mid-size class, suited for feeding a single machine station or a short distribution line.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 40 um element handling filtration. The nylon bowl holds 100 cc of condensate, while the separate 185 cc oil bowl feeds the lubricator. A circular gauge with an MPa/psi scale is fitted, and the reverse-flow valve is included per the K code.
| Model | Airtac GAFC Air Service Unit GAFC400N15LK |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-station clamping fixture on a CNC machine where the lower pressure range protects delicate workpieces from over-clamping.
Operate a pneumatic stop gate on a packaging line, using the 0.15-0.4 MPa range to control gentle product handling without sudden impacts.
Supply filtered, regulated air to a laboratory test bench where a lower pressure ceiling is required for sensitive pneumatic instruments.
Choose this GAFC400N15LK when your circuit needs a 1/2in port and a regulated output capped at 0.4 MPa (20-58 psi). The nylon bowl is a build choice, not a performance upgrade; the shared specification of 1.0 MPa max and -5 to 70 C applies regardless, so confirm the material suits your environment. The semi-auto drain dumps condensate on pressure drop, with a manual backup for on-demand use. The 40 um element is the standard grade, and the PT thread means the fitted gauge reads in MPa and psi. The K code adds the reverse-flow valve, which the catalogue shows as a separate symbol. For spares, the filter-regulator is GAFR400-15 and the lubricator is GAL400-15, both orderable separately. Since the lubricator is meant to carry oil, if your line must stay oil-free, omit this unit and choose a plain GAFR filter-regulator instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.
The GAFC400N15LK operates on air with a lower pressure range of 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 100 cc drain bowl and a 185 cc oil bowl, weighs 1810 g, and the recommended lubricant is ISO VG 32.
The K code indicates the reverse-flow (reflux) valve is fitted. The catalogue draws this as a separate pneumatic symbol. It is an ordering difference to be aware of; the valve is included with this model.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.