verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400N15SNK

The AirTAC Airtac GAFC Air Service Unit GAFC400N15SNK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$113.61 $124.97Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400N15SNK

This GAFC400N15SNK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/2in port and 1810 g mass place it in the mid-size class, suited for distribution to multiple actuators or a small machine header rather than a single cylinder.

Air enters the first body where the 40 um element removes solids and moisture, and the regulator sets pressure within 0.15-0.9 MPa (20-130 psi). The lubricator then adds a controlled oil mist downstream, so oil never travels back through the regulator seat. The nylon bowl is specified by the N code; the catalogue gives no material-specific ratings, so confirm it suits your environment. No gauge is supplied, but the 1/4in gauge connection allows one to be added later.

Airtac GAFC Air Service Unit GAFC400N15SNK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400N15SNK
SeriesGAFC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC400N15SNK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-15 filter & regulator, GAL400-15 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 1/2" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400N15SNK Is Used

precision_manufacturing

Machine tool lubrication

Feed a 1/2in line to a CNC lathe's tool changer and door cylinders, where the regulated 0.15-0.9 MPa range covers typical actuation and the oil mist keeps sliding ways moving freely.

factory

Assembly station air prep

Supply a multi-operator workbench with filtered, pressure-set air for pneumatic screwdrivers and push-in fittings, with the 185 cc oil bowl reducing how often the lubricator needs topping up.

conveyor_belt

Packaging line transfer

Operate a section of belt diverters and stops on a packaging line, where the 100 cc condensate bowl captures moisture from a humid plant and the semi-auto drain clears it at each pressure drop.

Is the Airtac GAFC Air Service Unit GAFC400N15SNK the Right Air-Prep Unit?

Choose the GAFC400 body for medium-flow circuits; its catalogue flow curve is plotted to 6000 L/min at 0.7 MPa inlet, roughly 70% more than the GAFC300's 3500 L/min envelope. The N code specifies a nylon bowl, while the blank default is PC and C is metal; all share the same 1.0 MPa maximum and -5 to 70 C rating. This unit has the semi-auto drain (dumps on pressure drop) plus a manual drain for on-demand use, and the 40 um element is the standard grade. The K suffix means the reverse-flow (reflux) valve is fitted, shown as a separate symbol in the catalogue. Spare parts are orderable as GAFR400-15 and GAL400-15. With a 1.0 MPa max supply, there is about 0.1 MPa above the 0.9 MPa top of the regulated range, so plan inlet pressure carefully if you need the full output.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-15 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400N15SNK FAQ

It is an F.R.L. combination with a 1/2in port, working pressure 0.15-0.9 MPa (20-130 psi), max pressure 1.0 MPa (145 psi), proof pressure 1.5 MPa (215 psi), temperature range -5 to 70 C, 40 um element, 100 cc drain bowl, 185 cc oil bowl, and weight 1810 g. Use ISO VG 32 oil in the lubricator.

The N after the port code means no gauge is supplied; the GAFC400 body has a 1/4in gauge connection if you add one later. The K code means the reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol. The nylon bowl is specified by the N before the port code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400N15SNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400N15SNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.