The AirTAC Airtac GAFC Air Service Unit GAFC50020ASNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This AirTAC F.R.L. combination pairs a filter-regulator with a lubricator on one T-bracket, so the air is cleaned, set to pressure, then oil-misted in the last stage. The GAFC50020ASNW uses a 3/4in port, weighs 1910 g, and holds 108 cc of condensate plus 225 cc of oil in two separate bowls.
The standard pressure range is 0.15-0.9 MPa (20-130 psi) with a 5 um element that traps finer particles for sensitive equipment. The automatic drain clears water without an operator, and since no gauge is fitted, the 1/4in gauge connection is ready for a later add-on if needed.
| Model | Airtac GAFC Air Service Unit GAFC50020ASNW |
|---|---|
| Series | GAFC500 F.R.L. combination |
| Port size | 3/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 108 cc |
| Capacity of oil bowl | 225 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1910 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC500 is 1/4" if you add one.
| GAFC500 | GA500 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 20 | Port size 3/4". This body offers 20 = 3/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR500-20 filter & regulator, GAL500-20 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC500 · 3/4" · curve to 7000 L/min |
|---|---|
| One size down | GAFC400 |
| One size up | GAFC600 (curve to 12000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feeds a 3/4in header on a CNC machining center, supplying filtered and lubricated air to multiple cylinders and valves.
Provides regulated, oil-misted air to pneumatic actuators on a multi-station assembly conveyor, with the automatic drain reducing maintenance stops.
Supplies clean, pressure-controlled air to film-sealing and carton-erecting machines where consistent lubrication extends cylinder life.
Choose the GAFC500 for a 3/4in line feeding a machine header or multi-station setup; the 7000 L/min plotted flow curve at 0.7 MPa inlet shows its sizing envelope. The PC bowl is the standard build, the automatic drain suits unattended operation, and the 5 um element trades finer filtration for more frequent service. Spare parts are GAFR500-20 and GAL500-20, both orderable separately.
With no gauge supplied, the 1/4in connection accepts one later. The 1.0 MPa max supply leaves about 0.1 MPa above the 0.9 MPa top of the range, so plan the inlet pressure carefully if you need the full output.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR500-20 filter-regulator on that branch instead of the full combination.
The working pressure range is 0.15-0.9 MPa (20-130 psi), with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, uses ISO VG 32 oil, has a 108 cc drain bowl and 225 cc oil bowl, and weighs 1910 g.
The N after the port code means no gauge is supplied. The GAFC500 has a 1/4in gauge connection, so you can add a circular gauge later to read the set pressure directly.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.